power edge r210 with s100 raid

$
0
0

hi i have PE r210 with s100 raid with  2*1 tb hard disk wish was raid 1 (mirror ) and because of power failure the hard disk 0 was not detected and the raid is degraded so i took the bad hard disk and format it and then delete the volume to be partitioned then i put it back in the server and it gave me ready

i initialize it for prec and assign it in hot spare and the disk give me now spare but it is not rebuilding the array ? and it is doing nothing so can anyone tell me where i was wrong

please advice   


2950 RAID5 HDD replacement

$
0
0

Hi,

We have one disk failure in a RAID 5 system in PowerEdge 2950 with Perc 6i RAID card. Original HDD is WD SATA 7200 rpm 1 TB.

Since Dell doesn't sell the original model of HDD anymore, the Dell sales rep sold us a compatible HDD, probably not from WD. Although she said it will rebuild the RAID, I still want to double check here. Can we use this compatible HDD to rebuild the RAID without data loss? Does Dell make sure the replacement HDD has same number of cylinders, sectors, etc? Or does it not matter?

Do we just shut down the server, swap out the faulty HDD, power on, and configure BIOS to rebuild the RAID5?

Thank you very much for reviewing my question!

-Andrew

2950 3TB with H310

$
0
0

Hello, I am looking to use 3TB drives in a raid 5 in my 2950. Will a H310 accomplish this or will I need to go up to the 700?  Anyother card recomendations are welcome as well. Thank you.

Hyper-V Server 2012 R2 on Dell R510 - how to check RAID Health?

$
0
0

Hello, guys!

I have Poweredge R510 with Hyper-V Server 2012 R2 as host OS. I suspect hardware problems and I need to check disk consistency. What software should I use with Hyper-V Server? Need to verify RAID health. During server boot I see no errors in SAS Configuration utility.

In the Event Log I see:

EventID 11 The driver detected a controller error on \Device\RaidPort0.

EventID 153 The IO operation at logical block address 2b0 for Disk 0 (PDO name: \Device\0000003f) was retried.

Thank you!

PE 1900 w/PERC 5i RAID controller will not boot, I think because HD is full? Please help

$
0
0

Hi, I have a PowerEdge 1900 server with Perc 5i RAID5 controller that will not boot.  I am a novice so please excuse me if I do not use the correct terminology.

The server is in a different room from the lab.  Last Monday morning, a student was trying to back up images to the server and could not connect.  I checked other PCs and the connection was gone from all.  I went to the server and it was off.  I started it again, got the Dell Poweredge 1900 screen, then it went through what I think is called the BIOS, with white letters on the black screen saying the usual things like amount of memory, the logical devices installed, etc.  It went through that usual procedure and got to the Windows Server 2003 screen, got the progress bar for a few seconds, then instead of loading, it went back to the Dell Poweredge 1900 screen, began the BIOS stage again, and keeps doing that over and over.  

I pressed F8 and tried to load in Safe Mode.  It does not boot, just goes back to the Dell Poweredge screen and starts the cycle again.  I pressed F8 again and chose Last Known Good Configuration, still will not boot.

I pressed F11, put the Server 2003 Disk 1 in the CD drive, selected Boot from CD, I get the Windows Setup screen, it says it is loading what it needs.  I get to Recovery and ask to Repair OS, and it tells me that is cannot find the hard drive, and I have to exit.

I pressed F10 and ran a full diagnostic.  The 4 physical HD's were all tested and passed, no issues.  The only errors were related to Low Battery on the Storage ROMB battery (error codes 2900:0221 and 2900:0325).  No other errors.  I ordered a replacement battery, received it, replaced it on the RAID controller, turned everything on and it still did not boot, just went through the endless cycle again.  I figured the RAID controller battery needed to charge for a day, so I went into F2 to keep the server from going through the continuous cycle so the battery could charge.

This morning I restarted again and still the same cycle.  I ran a new complete diagnostic and the only error was 2900:0221, IPML system Event log check, referencing the failed battery.  From what I have read, that is a notice from the failure and will stay in the log until I can clear it (which I cannot do because it will not boot).

In the mean time, I have been reading various posts in this forum to try to learn what is happening.  I learned to check the RAID configuration in case a physical drive was wrong.  I started the system again and Control R to run the RAID config utility.  The 4 physical drives are all listed as online, but the available space is 0 MB.

Does available Space = 0 mean the HD is completely filled?  That I assume would prevent the OS from loading?  

If that is correct, can someone tell me how I might be able to delete files from the HD when the OS will not boot, and booting from disk does not work because it cannot find the HD (because it is full?)?

If you think that the problem is something else, I am happy to hear suggestions.  I am at a loss how to proceed.

Thank you for your kind assistance.

PowerEdge 2950 Per6I SCSI sense data Sense key: 4 Sense code: 35 Sense qualifier: 5

$
0
0

Hello

I reciently pulled the perc 6i logs on all of my 2950's

One system reports the following about once a day since last time it was shutdown on 12/20/13.  (FWIW there was a time in Jan where it did not report the error for 6 days.)

02/28/14 15:59:23: EVT#16791-02/28/14 15:59:23: 113=Unexpected sense: Encl PD 20 Path 5001e0f0380ce100, CDB: 12 00 00 00 04 00, Sense: 4/35/05

02/28/14 15:59:23: Raw Sense for PD 20: 70 00 04 00 00 00 00 0a 00 00 00 00 35 05 00 00 00 00
02/28/14 15:59:23: SES_GenericCallback: enclPd=20...RDM_STATUS =2 retries: 0
02/28/14 15:59:23: Cmd Details: 1c 01 02 00 04 00 
02/28/14 15:59:23: CDB: 1c 01 02 00 04 00 00 00 08 00 00 00 00 00 b0 00 LEN=6

02/28/14 15:59:23: Sense Data at: a0862840 
02/28/14 15:59:23: responseCode: 70 valid: 0 segmentNumber: 0 senseKey: 4 ili: 0 eom: 0 filemark: 0 information: 0 additionalSenseLength: a commandSepcificInfo: 0 asc: 35 ascq: 5 fruCode: 0 sksv: 0 fieldPointer: 0 
02/28/14 15:59:23: SES_HandleCheckCondition: Reissued SN_HARDWARE_ERROR: 1c enclPd=20

the SCSI spec identifies this as the following...

43505Hardware Error - enclosure services checksum error

Hoping someone has some input as to what's this error is trying to tell me????

The system appears to be operating normally and patrol reads complete as expected. I have not done a consistency check for quite some time.

 I think I'll down the system this weekend and re-seat the cables etc....

----More info-----

Drives are SEAGATE  ST3300655SS (6 of them in raid 6)

Versions
================
Product Name : PERC 6/i Integrated
FW Package Build: 6.3.1-0003


Image Versions in Flash:
================
FW Version : 1.22.32-1371
BIOS Version : 2.04.00
WebBIOS Version : 1.1-46-e_15-Rel
Ctrl-R Version : 1.02-015B
Preboot CLI Version: 01.00-022:#%00005
Boot Block Version : 1.00.00.01-0011

Adapter 0 -- Virtual Drive Information:

Virtual Drive: 0 (Target Id: 0)
Name :RAID
RAID Level : Primary-6, Secondary-0, RAID Level Qualifier-3
Size : 1.088 TB
Sector Size : 512
Parity Size : 557.75 GB
State : Optimal
Strip Size : 128 KB
Number Of Drives : 6
Span Depth : 1
Default Cache Policy: WriteBack, ReadAdaptive, Direct, No Write Cache if Bad BBU
Current Cache Policy: WriteBack, ReadAdaptive, Direct, No Write Cache if Bad BBU
Default Access Policy: Read/Write
Current Access Policy: Read/Write
Disk Cache Policy : Disk's Default
Encryption Type : None
Is VD Cached: No

 

Hard drives for R710 Perc 6i

$
0
0

I have an old R710 with a Perc 6i controller and I want to repurpose it as basic file storage box. It's out of warranty and I don't want to buy Dell branded drives for 2x the price as other enterprise drives. Don't expect a drive compatibility list to be floating around, but any info or shared experience using non Dell-branded drives on a Perc 6i would be nice to have.

PowerEdge 2650 takes longer BIOS boot with more RAM

$
0
0

I bought 8 more GB RAM for my PE 2650, which had 4 GB originally. When I installed the 12 GB RAM, the server takes about 10 minutes to load, at the Dell splash screen, compared to 3 minutes with 4 GB RAM. What is causing the server to boot so long. Is it the POST Diagnostics? Is there anyway I can make it faster?


T20 Builtin Intel RAID.....

$
0
0

Having an issue with the Intel Rapid Storage RAID....

Windows 2012

4 Drives:  1 SSD OS, 3 4gig SATAs...

Was able to install OS on SSD.

After it was running fine, I turned on the RAID in BIOS.    Couldnt boot.    Tried to reinstall Windows saw old install.


Cant figure out what the problem is.   Turned on and off RAID in Dell BIOS.  Nothing.

Help......

Steve

T320 Raid with 2.5 inch drive trays

$
0
0
Have a T710 with 2.5 in dell drive trays. Will this work with the T320 if so what arrangement of the drives 2.5 Rack or other? Thanks

R900 LCD message LDC-MVS04

$
0
0

Hi wonder if anyone can help with a problem we have on a Dell R900.

First of all the server crashed and when we inspected it the LCD display was amber saying there was a memory issue.

We opened up the server and "reseated" the meory modules, re started the server and it booted OK (Windows 2003 Ent)

We ran server manager and memory and everything else  reported OK, however front LCD scrolling screen now is in a darker blue than my other R900's and scrolling message says -

LDC-MVS04

I have look all over on the web and can find no reference to this error, can anyone help me?

 

thanks

 

Peter

 

 

 

Alarm in Disk

$
0
0

Hello my PE R710 present a alarm in disk 1 the log is this    could someonetell meaboutthis disk

 

Alert Log

Alert Log contains...

Severity : Ok
ID : 2095
Date and Time : Wed Mar 12 13:59:21 2014
Category : Storage Service
Description : Unexpected sense. SCSI sense data: Sense key: 5 Sense code: 24 Sense qualifier: 0: Physical Disk 0:0:1 Controller 0, Connector 0

Severity : Ok
ID : 2095
Date and Time : Wed Mar 12 13:59:20 2014
Category : Storage Service
Description : Unexpected sense. SCSI sense data: Sense key: 5 Sense code: 24 Sense qualifier: 0: Physical Disk 0:0:1 Controller 0, Connector 0

Severity : Critical
ID : 1554
Date and Time : Mon Mar 10 18:23:41 2014
Category : Instrumentation Service
Description : Log size is full
Log type: ESM

Severity : Non-Critical
ID : 1553
Date and Time : Sun Mar 09 19:42:59 2014
Category : Instrumentation Service
Description : Log size is near or at capacity
Log type: ESM

Severity : Ok
ID : 2243
Date and Time : Sat Mar 08 09:35:45 2014
Category : Storage Service
Description : The Patrol Read has stopped.: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2242
Date and Time : Sat Mar 08 03:14:50 2014
Category : Storage Service
Description : The Patrol Read has started.: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 1552
Date and Time : Wed Mar 05 12:13:55 2014
Category : Instrumentation Service
Description : Log size is no longer near or at capacity
Log type: ESM

Severity : Ok
ID : 2243
Date and Time : Sat Mar 01 09:32:10 2014
Category : Storage Service
Description : The Patrol Read has stopped.: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2242
Date and Time : Sat Mar 01 03:14:45 2014
Category : Storage Service
Description : The Patrol Read has started.: Controller 0 (PERC H700 Integrated)

Severity : Critical
ID : 1554
Date and Time : Thu Feb 27 08:41:28 2014
Category : Instrumentation Service
Description : Log size is full
Log type: ESM

Severity : Non-Critical
ID : 1553
Date and Time : Wed Feb 26 06:00:39 2014
Category : Instrumentation Service
Description : Log size is near or at capacity
Log type: ESM

Severity : Ok
ID : 2124
Date and Time : Wed Feb 26 01:50:35 2014
Category : Storage Service
Description : Redundancy normal: Virtual Disk 1 (PERC H700 Integrated) Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2092
Date and Time : Wed Feb 26 01:50:34 2014
Category : Storage Service
Description : Physical disk Rebuild completed: Physical Disk 0:0:1 Controller 0, Connector 0

Severity : Ok
ID : 2158
Date and Time : Wed Feb 26 01:50:34 2014
Category : Storage Service
Description : Physical disk online: Physical Disk 0:0:1 Controller 0, Connector 0

Severity : Ok
ID : 2121
Date and Time : Wed Feb 26 01:50:34 2014
Category : Storage Service
Description : Device returned to normal: Virtual Disk 0 (PERC H700 Integrated) Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2124
Date and Time : Wed Feb 26 01:50:34 2014
Category : Storage Service
Description : Redundancy normal: Virtual Disk 0 (PERC H700 Integrated) Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2121
Date and Time : Wed Feb 26 01:50:34 2014
Category : Storage Service
Description : Device returned to normal: Virtual Disk 1 (PERC H700 Integrated) Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2358
Date and Time : Tue Feb 25 22:49:59 2014
Category : Storage Service
Description : The battery charge cycle is complete.: Battery 0 Controller 0

Severity : Ok
ID : 2065
Date and Time : Tue Feb 25 20:30:12 2014
Category : Storage Service
Description : Physical disk Rebuild started: Physical Disk 0:0:1 Controller 0, Connector 0

Severity : Ok
ID : 2098
Date and Time : Tue Feb 25 20:30:11 2014
Category : Storage Service
Description : Global hot spare assigned: Physical Disk 0:0:1 Controller 0, Connector 0

Severity : Ok
ID : 2199
Date and Time : Tue Feb 25 19:06:50 2014
Category : Storage Service
Description : The virtual disk cache policy has changed.: Virtual Disk 1 (PERC H700 Integrated) Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2189
Date and Time : Tue Feb 25 19:06:49 2014
Category : Storage Service
Description : The controller write policy has been changed to Write Back.: Battery 0 Controller 0

Severity : Ok
ID : 2199
Date and Time : Tue Feb 25 19:06:49 2014
Category : Storage Service
Description : The virtual disk cache policy has changed.: Virtual Disk 0 (PERC H700 Integrated) Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2247
Date and Time : Tue Feb 25 18:12:39 2014
Category : Storage Service
Description : The controller battery is charging.: Battery 0 Controller 0

Severity : Ok
ID : 2177
Date and Time : Tue Feb 25 18:12:24 2014
Category : Storage Service
Description : The controller battery Learn cycle has completed.: Battery 0 Controller 0

Severity : Ok
ID : 2199
Date and Time : Tue Feb 25 17:33:26 2014
Category : Storage Service
Description : The virtual disk cache policy has changed.: Virtual Disk 0 (PERC H700 Integrated) Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2199
Date and Time : Tue Feb 25 17:33:26 2014
Category : Storage Service
Description : The virtual disk cache policy has changed.: Virtual Disk 1 (PERC H700 Integrated) Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2188
Date and Time : Tue Feb 25 17:33:25 2014
Category : Storage Service
Description : The controller write policy has been changed to Write Through.: Battery 0 Controller 0

Severity : Ok
ID : 2358
Date and Time : Tue Feb 25 15:49:19 2014
Category : Storage Service
Description : The battery charge cycle is complete.: Battery 0 Controller 0

Severity : Ok
ID : 2176
Date and Time : Tue Feb 25 15:49:19 2014
Category : Storage Service
Description : The controller battery Learn cycle has started.: Battery 0 Controller 0

Severity : Ok
ID : 2334
Date and Time : Tue Feb 25 13:08:02 2014
Category : Storage Service
Description : Controller event log: Unexpected sense: Encl PD 20 Path 5942b0b05992f600, CDB: 1c 01 a0 00 04 00, Sense: 5/24/00: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Feb 25 13:08:02 2014
Category : Storage Service
Description : Controller event log: Unexpected sense: Encl PD 20 Path 5942b0b05992f600, CDB: 1c 01 a0 00 04 00, Sense: 5/24/00: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Feb 25 13:08:02 2014
Category : Storage Service
Description : Controller event log: Unexpected sense: Encl PD 20 Path 5942b0b05992f600, CDB: 1c 01 a0 00 04 00, Sense: 5/24/00: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Feb 25 13:08:01 2014
Category : Storage Service
Description : Controller event log: Battery started charging: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Feb 25 13:08:01 2014
Category : Storage Service
Description : Controller event log: Battery relearn pending: Battery is under charge: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Feb 25 13:08:01 2014
Category : Storage Service
Description : Controller event log: Unexpected sense: PD 01(e0x20/s1) Path 50000c0f01270a02, CDB: 12 01 dc 01 1d 00, Sense: 5/24/00: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Feb 25 13:08:01 2014
Category : Storage Service
Description : Controller event log: Unexpected sense: Encl PD 20 Path 5942b0b05992f600, CDB: 1c 01 a0 00 04 00, Sense: 5/24/00: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Feb 25 13:08:00 2014
Category : Storage Service
Description : Controller event log: Inserted: PD 05(e0x20/s5): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Feb 25 13:08:00 2014
Category : Storage Service
Description : Controller event log: Time established as 02/25/14 13:05:54; (63 seconds since power on): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Feb 25 13:08:00 2014
Category : Storage Service
Description : Controller event log: Battery temperature is normal: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Feb 25 13:08:00 2014
Category : Storage Service
Description : Controller event log: Current capacity of the battery is above threshold: Controller 0 (PERC H700 Integrated)

Severity : Non-Critical
ID : 2335
Date and Time : Tue Feb 25 13:07:59 2014
Category : Storage Service
Description : Controller event log: PD 01(e0x20/s1) is not a certified drive: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Feb 25 13:07:59 2014
Category : Storage Service
Description : Controller event log: Inserted: PD 02(e0x20/s2): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Feb 25 13:07:59 2014
Category : Storage Service
Description : Controller event log: Inserted: PD 03(e0x20/s3): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Feb 25 13:07:59 2014
Category : Storage Service
Description : Controller event log: Inserted: PD 04(e0x20/s4): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Feb 25 13:07:58 2014
Category : Storage Service
Description : Controller event log: Enclosure PD 20(c None/p0) communication restored: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Feb 25 13:07:58 2014
Category : Storage Service
Description : Controller event log: Inserted: Encl PD 20: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Feb 25 13:07:58 2014
Category : Storage Service
Description : Controller event log: Inserted: PD 00(e0x20/s0): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Feb 25 13:07:58 2014
Category : Storage Service
Description : Controller event log: Inserted: PD 01(e0x20/s1): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Feb 25 13:07:57 2014
Category : Storage Service
Description : Controller event log: Firmware initialization started (PCI ID 0079/1000/1f17/1028): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Feb 25 13:07:57 2014
Category : Storage Service
Description : Controller event log: Battery Present: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Feb 25 13:07:57 2014
Category : Storage Service
Description : Controller event log: Package version 12.10.6-0001: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Feb 25 13:07:57 2014
Category : Storage Service
Description : Controller event log: Board Revision A03: Controller 0 (PERC H700 Integrated)

Severity : Non-Critical
ID : 2335
Date and Time : Tue Feb 25 13:07:56 2014
Category : Storage Service
Description : Controller event log: VD 01/1 is now DEGRADED: Controller 0 (PERC H700 Integrated)

Severity : Non-Critical
ID : 2335
Date and Time : Tue Feb 25 13:07:56 2014
Category : Storage Service
Description : Controller event log: VD 00/0 is now DEGRADED: Controller 0 (PERC H700 Integrated)

Severity : Non-Critical
ID : 2335
Date and Time : Tue Feb 25 13:07:56 2014
Category : Storage Service
Description : Controller event log: VD 01/1 is now DEGRADED: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Feb 25 13:07:56 2014
Category : Storage Service
Description : Controller event log: Time established as 02/25/14 12:52:43; (314 seconds since power on): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Feb 25 13:07:55 2014
Category : Storage Service
Description : Controller event log: Current capacity of the battery is above threshold: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Feb 25 13:07:55 2014
Category : Storage Service
Description : Controller event log: Battery started charging: Controller 0 (PERC H700 Integrated)

Severity : Non-Critical
ID : 2335
Date and Time : Tue Feb 25 13:07:55 2014
Category : Storage Service
Description : Controller event log: VD 00/0 is now DEGRADED: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Feb 25 13:07:55 2014
Category : Storage Service
Description : Controller event log: State change on VD 01/1 from OPTIMAL(3) to DEGRADED(2): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Feb 25 13:07:54 2014
Category : Storage Service
Description : Controller event log: Inserted: PD 05(e0x20/s5): Controller 0 (PERC H700 Integrated)

Severity : Non-Critical
ID : 2335
Date and Time : Tue Feb 25 13:07:54 2014
Category : Storage Service
Description : Controller event log: PD missing: SasAddr=0x50000c0f01d92396, ArrayRef=0, RowIndex=0x1, EnclPd=0x20, Slot=1.
: Controller 0 (PERC H700 Integrated)

Severity : Non-Critical
ID : 2335
Date and Time : Tue Feb 25 13:07:54 2014
Category : Storage Service
Description : Controller event log: PDs missing from configuration at boot: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Feb 25 13:07:54 2014
Category : Storage Service
Description : Controller event log: Battery temperature is normal: Controller 0 (PERC H700 Integrated)

Severity : Non-Critical
ID : 2335
Date and Time : Tue Feb 25 13:07:53 2014
Category : Storage Service
Description : Controller event log: PD 01(e0x20/s1) is not a certified drive: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Feb 25 13:07:53 2014
Category : Storage Service
Description : Controller event log: Inserted: PD 02(e0x20/s2): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Feb 25 13:07:53 2014
Category : Storage Service
Description : Controller event log: Inserted: PD 03(e0x20/s3): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Feb 25 13:07:53 2014
Category : Storage Service
Description : Controller event log: Inserted: PD 04(e0x20/s4): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Feb 25 13:07:52 2014
Category : Storage Service
Description : Controller event log: Enclosure PD 20(c None/p0) communication restored: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Feb 25 13:07:52 2014
Category : Storage Service
Description : Controller event log: Inserted: Encl PD 20: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Feb 25 13:07:52 2014
Category : Storage Service
Description : Controller event log: Inserted: PD 00(e0x20/s0): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Feb 25 13:07:52 2014
Category : Storage Service
Description : Controller event log: Inserted: PD 01(e0x20/s1): Controller 0 (PERC H700 Integrated)

Severity : Non-Critical
ID : 2057
Date and Time : Tue Feb 25 13:07:51 2014
Category : Storage Service
Description : Virtual disk degraded: Virtual Disk 1 (PERC H700 Integrated) Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Feb 25 13:07:51 2014
Category : Storage Service
Description : Controller event log: Shutdown command received from host: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Feb 25 13:07:51 2014
Category : Storage Service
Description : Controller event log: Firmware initialization started (PCI ID 0079/1000/1f17/1028): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Feb 25 13:07:51 2014
Category : Storage Service
Description : Controller event log: Battery has been replaced: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Feb 25 13:07:51 2014
Category : Storage Service
Description : Controller event log: Package version 12.10.6-0001: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Feb 25 13:07:51 2014
Category : Storage Service
Description : Controller event log: Board Revision A03: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Feb 25 13:07:51 2014
Category : Storage Service
Description : Controller event log: Unexpected sense: Encl PD 20 Path 5942b0b05992f600, CDB: 1c 01 00 00 20 00, Sense: 6/29/00: Controller 0 (PERC H700 Integrated)

Severity : Non-Critical
ID : 2057
Date and Time : Tue Feb 25 13:07:50 2014
Category : Storage Service
Description : Virtual disk degraded: Virtual Disk 0 (PERC H700 Integrated) Controller 0 (PERC H700 Integrated)

Severity : Non-Critical
ID : 2359
Date and Time : Tue Feb 25 13:07:49 2014
Category : Storage Service
Description : Disk found is not supplied by an authorized hardware provider: Physical Disk 0:0:1 Controller 0, Connector 0

Severity : Ok
ID : 1000
Date and Time : Tue Feb 25 13:07:43 2014
Category : Instrumentation Service
Description : Server Administrator starting

Severity : Ok
ID : 1012
Date and Time : Tue Feb 25 13:07:43 2014
Category : Instrumentation Service
Description : IPMI status
Interface: User

Severity : Ok
ID : 1001
Date and Time : Tue Feb 25 13:07:43 2014
Category : Instrumentation Service
Description : Server Administrator startup complete

Severity : Ok
ID : 1008
Date and Time : Tue Feb 25 13:07:43 2014
Category : Instrumentation Service
Description : Systems Management Data Manager Started

Severity : Ok
ID : 1552
Date and Time : Mon Feb 24 09:18:42 2014
Category : Instrumentation Service
Description : Log size is no longer near or at capacity
Log type: ESM

Severity : Ok
ID : 1152
Date and Time : Sat Feb 22 20:33:14 2014
Category : Instrumentation Service
Description : Voltage sensor returned to a normal value
Sensor location: PS 1 Voltage
Chassis location: Main System Chassis
Previous state was: Unknown
Voltage sensor value (in Volts): 120.000

Severity : Ok
ID : 1152
Date and Time : Sat Feb 22 20:33:14 2014
Category : Instrumentation Service
Description : Voltage sensor returned to a normal value
Sensor location: PS 2 Voltage
Chassis location: Main System Chassis
Previous state was: Unknown
Voltage sensor value (in Volts): 120.000

Severity : Ok
ID : 1151
Date and Time : Sat Feb 22 20:31:32 2014
Category : Instrumentation Service
Description : Voltage sensor value unknown
Sensor location: PS 1 Voltage
Chassis location: Main System Chassis
Previous state was: OK (Normal)
Voltage sensor value (in Volts): 0.000

Severity : Ok
ID : 1151
Date and Time : Sat Feb 22 20:31:32 2014
Category : Instrumentation Service
Description : Voltage sensor value unknown
Sensor location: PS 2 Voltage
Chassis location: Main System Chassis
Previous state was: OK (Normal)
Voltage sensor value (in Volts): 0.000

Severity : Critical
ID : 1554
Date and Time : Sat Feb 22 16:28:28 2014
Category : Instrumentation Service
Description : Log size is full
Log type: ESM

Severity : Non-Critical
ID : 1553
Date and Time : Sat Feb 22 15:12:33 2014
Category : Instrumentation Service
Description : Log size is near or at capacity
Log type: ESM

Severity : Ok
ID : 2243
Date and Time : Sat Feb 22 09:58:23 2014
Category : Storage Service
Description : The Patrol Read has stopped.: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2242
Date and Time : Sat Feb 22 03:14:39 2014
Category : Storage Service
Description : The Patrol Read has started.: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2095
Date and Time : Wed Feb 19 12:13:56 2014
Category : Storage Service
Description : Unexpected sense. SCSI sense data: Sense key: 5 Sense code: 24 Sense qualifier: 0: Enclosure 0:0 Controller 0, Connector 0

Severity : Ok
ID : 2095
Date and Time : Wed Feb 19 12:11:40 2014
Category : Storage Service
Description : Unexpected sense. SCSI sense data: Sense key: 5 Sense code: 24 Sense qualifier: 0: Physical Disk 0:0:1 Controller 0, Connector 0

Severity : Ok
ID : 2095
Date and Time : Wed Feb 19 12:11:40 2014
Category : Storage Service
Description : Unexpected sense. SCSI sense data: Sense key: 5 Sense code: 24 Sense qualifier: 0: Physical Disk 0:0:1 Controller 0, Connector 0

Severity : Ok
ID : 2358
Date and Time : Wed Feb 19 10:13:07 2014
Category : Storage Service
Description : The battery charge cycle is complete.: Battery 0 Controller 0

Severity : Ok
ID : 2334
Date and Time : Wed Feb 19 09:37:24 2014
Category : Storage Service
Description : Controller event log: Unexpected sense: Encl PD 20 Path 5942b0b05992f600, CDB: 1c 01 a0 00 04 00, Sense: 5/24/00: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Feb 19 09:37:24 2014
Category : Storage Service
Description : Controller event log: Unexpected sense: Encl PD 20 Path 5942b0b05992f600, CDB: 1c 01 a0 00 04 00, Sense: 5/24/00: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Feb 19 09:37:24 2014
Category : Storage Service
Description : Controller event log: Unexpected sense: Encl PD 20 Path 5942b0b05992f600, CDB: 1c 01 a0 00 04 00, Sense: 5/24/00: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Feb 19 09:37:23 2014
Category : Storage Service
Description : Controller event log: Current capacity of the battery is above threshold: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Feb 19 09:37:23 2014
Category : Storage Service
Description : Controller event log: Battery started charging: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Feb 19 09:37:23 2014
Category : Storage Service
Description : Controller event log: Unexpected sense: PD 01(e0x20/s1) Path 50000c0f01d92396, CDB: 12 01 dc 01 1d 00, Sense: 5/24/00: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Feb 19 09:37:23 2014
Category : Storage Service
Description : Controller event log: Unexpected sense: Encl PD 20 Path 5942b0b05992f600, CDB: 1c 01 a0 00 04 00, Sense: 5/24/00: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Feb 19 09:37:22 2014
Category : Storage Service
Description : Controller event log: Inserted: PD 04(e0x20/s4): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Feb 19 09:37:22 2014
Category : Storage Service
Description : Controller event log: Inserted: PD 05(e0x20/s5): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Feb 19 09:37:22 2014
Category : Storage Service
Description : Controller event log: Time established as 02/19/14 9:33:18; (63 seconds since power on): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Feb 19 09:37:22 2014
Category : Storage Service
Description : Controller event log: Battery temperature is normal: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Feb 19 09:37:21 2014
Category : Storage Service
Description : Controller event log: Inserted: PD 01(e0x20/s1): Controller 0 (PERC H700 Integrated)

Severity : Non-Critical
ID : 2335
Date and Time : Wed Feb 19 09:37:21 2014
Category : Storage Service
Description : Controller event log: PD 01(e0x20/s1) is not a certified drive: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Feb 19 09:37:21 2014
Category : Storage Service
Description : Controller event log: Inserted: PD 02(e0x20/s2): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Feb 19 09:37:21 2014
Category : Storage Service
Description : Controller event log: Inserted: PD 03(e0x20/s3): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Feb 19 09:37:20 2014
Category : Storage Service
Description : Controller event log: Board Revision A03: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Feb 19 09:37:20 2014
Category : Storage Service
Description : Controller event log: Enclosure PD 20(c None/p0) communication restored: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Feb 19 09:37:20 2014
Category : Storage Service
Description : Controller event log: Inserted: Encl PD 20: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Feb 19 09:37:20 2014
Category : Storage Service
Description : Controller event log: Inserted: PD 00(e0x20/s0): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Feb 19 09:37:19 2014
Category : Storage Service
Description : Controller event log: VD 01/1 is now OPTIMAL: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Feb 19 09:37:19 2014
Category : Storage Service
Description : Controller event log: Firmware initialization started (PCI ID 0079/1000/1f17/1028): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Feb 19 09:37:19 2014
Category : Storage Service
Description : Controller event log: Battery Present: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Feb 19 09:37:19 2014
Category : Storage Service
Description : Controller event log: Package version 12.10.6-0001: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Feb 19 09:37:18 2014
Category : Storage Service
Description : Controller event log: State change on PD 01(e0x20/s1) from OFFLINE(10) to ONLINE(18): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Feb 19 09:37:18 2014
Category : Storage Service
Description : Controller event log: State change on VD 00/0 from DEGRADED(2) to OPTIMAL(3): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Feb 19 09:37:18 2014
Category : Storage Service
Description : Controller event log: VD 00/0 is now OPTIMAL: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Feb 19 09:37:18 2014
Category : Storage Service
Description : Controller event log: State change on VD 01/1 from DEGRADED(2) to OPTIMAL(3): Controller 0 (PERC H700 Integrated)

Severity : Non-Critical
ID : 2335
Date and Time : Wed Feb 19 09:37:17 2014
Category : Storage Service
Description : Controller event log: VD 01/1 is now DEGRADED: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Feb 19 09:37:17 2014
Category : Storage Service
Description : Controller event log: Battery temperature is normal: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Feb 19 09:37:17 2014
Category : Storage Service
Description : Controller event log: Current capacity of the battery is above threshold: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Feb 19 09:37:17 2014
Category : Storage Service
Description : Controller event log: Battery started charging: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Feb 19 09:37:16 2014
Category : Storage Service
Description : Controller event log: State change on PD 01(e0x20/s1) from ONLINE(18) to OFFLINE(10): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Feb 19 09:37:16 2014
Category : Storage Service
Description : Controller event log: State change on VD 00/0 from OPTIMAL(3) to DEGRADED(2): Controller 0 (PERC H700 Integrated)

Severity : Non-Critical
ID : 2335
Date and Time : Wed Feb 19 09:37:16 2014
Category : Storage Service
Description : Controller event log: VD 00/0 is now DEGRADED: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Feb 19 09:37:16 2014
Category : Storage Service
Description : Controller event log: State change on VD 01/1 from OPTIMAL(3) to DEGRADED(2): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Feb 19 09:37:15 2014
Category : Storage Service
Description : Controller event log: Inserted: PD 03(e0x20/s3): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Feb 19 09:37:15 2014
Category : Storage Service
Description : Controller event log: Inserted: PD 04(e0x20/s4): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Feb 19 09:37:15 2014
Category : Storage Service
Description : Controller event log: Inserted: PD 05(e0x20/s5): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Feb 19 09:37:15 2014
Category : Storage Service
Description : Controller event log: Time established as 02/19/14 9:29:00; (63 seconds since power on): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Feb 19 09:37:14 2014
Category : Storage Service
Description : Controller event log: Inserted: PD 00(e0x20/s0): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Feb 19 09:37:14 2014
Category : Storage Service
Description : Controller event log: Inserted: PD 01(e0x20/s1): Controller 0 (PERC H700 Integrated)

Severity : Non-Critical
ID : 2335
Date and Time : Wed Feb 19 09:37:14 2014
Category : Storage Service
Description : Controller event log: PD 01(e0x20/s1) is not a certified drive: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Feb 19 09:37:14 2014
Category : Storage Service
Description : Controller event log: Inserted: PD 02(e0x20/s2): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Feb 19 09:37:13 2014
Category : Storage Service
Description : Controller event log: Package version 12.10.6-0001: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Feb 19 09:37:13 2014
Category : Storage Service
Description : Controller event log: Board Revision A03: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Feb 19 09:37:13 2014
Category : Storage Service
Description : Controller event log: Enclosure PD 20(c None/p0) communication restored: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Feb 19 09:37:13 2014
Category : Storage Service
Description : Controller event log: Inserted: Encl PD 20: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Feb 19 09:37:12 2014
Category : Storage Service
Description : Controller event log: Shutdown command received from host: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Feb 19 09:37:12 2014
Category : Storage Service
Description : Controller event log: Firmware initialization started (PCI ID 0079/1000/1f17/1028): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Feb 19 09:37:12 2014
Category : Storage Service
Description : Controller event log: Battery Present: Controller 0 (PERC H700 Integrated)

Severity : Non-Critical
ID : 2359
Date and Time : Wed Feb 19 09:35:14 2014
Category : Storage Service
Description : Disk found is not supplied by an authorized hardware provider: Physical Disk 0:0:1 Controller 0, Connector 0

Severity : Ok
ID : 1012
Date and Time : Wed Feb 19 09:35:09 2014
Category : Instrumentation Service
Description : IPMI status
Interface: User

Severity : Ok
ID : 1001
Date and Time : Wed Feb 19 09:35:09 2014
Category : Instrumentation Service
Description : Server Administrator startup complete

Severity : Ok
ID : 1008
Date and Time : Wed Feb 19 09:35:09 2014
Category : Instrumentation Service
Description : Systems Management Data Manager Started

Severity : Ok
ID : 1000
Date and Time : Wed Feb 19 09:35:08 2014
Category : Instrumentation Service
Description : Server Administrator starting

Severity : Ok
ID : 1552
Date and Time : Tue Feb 18 17:10:36 2014
Category : Instrumentation Service
Description : Log size is no longer near or at capacity
Log type: ESM

Severity : Ok
ID : 2095
Date and Time : Tue Feb 18 16:24:25 2014
Category : Storage Service
Description : Unexpected sense. SCSI sense data: Sense key: 5 Sense code: 24 Sense qualifier: 0: Enclosure 0:0 Controller 0, Connector 0

Severity : Ok
ID : 2095
Date and Time : Tue Feb 18 16:21:49 2014
Category : Storage Service
Description : Unexpected sense. SCSI sense data: Sense key: 5 Sense code: 24 Sense qualifier: 0: Physical Disk 0:1 Controller 0, Connector 0

Severity : Ok
ID : 2095
Date and Time : Tue Feb 18 16:21:49 2014
Category : Storage Service
Description : Unexpected sense. SCSI sense data: Sense key: 5 Sense code: 24 Sense qualifier: 0: Physical Disk 0:1 Controller 0, Connector 0

Severity : Ok
ID : 2243
Date and Time : Sat Feb 15 09:31:51 2014
Category : Storage Service
Description : The Patrol Read has stopped.: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2242
Date and Time : Sat Feb 15 03:14:36 2014
Category : Storage Service
Description : The Patrol Read has started.: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2243
Date and Time : Sat Feb 08 09:26:11 2014
Category : Storage Service
Description : The Patrol Read has stopped.: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2242
Date and Time : Sat Feb 08 03:14:31 2014
Category : Storage Service
Description : The Patrol Read has started.: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2243
Date and Time : Sat Feb 01 09:23:24 2014
Category : Storage Service
Description : The Patrol Read has stopped.: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2242
Date and Time : Sat Feb 01 03:14:26 2014
Category : Storage Service
Description : The Patrol Read has started.: Controller 0 (PERC H700 Integrated)

Severity : Critical
ID : 1554
Date and Time : Thu Jan 30 02:34:52 2014
Category : Instrumentation Service
Description : Log size is full
Log type: ESM

Severity : Non-Critical
ID : 1553
Date and Time : Thu Jan 30 00:06:14 2014
Category : Instrumentation Service
Description : Log size is near or at capacity
Log type: ESM

Severity : Ok
ID : 1552
Date and Time : Wed Jan 29 09:23:58 2014
Category : Instrumentation Service
Description : Log size is no longer near or at capacity
Log type: ESM

Severity : Critical
ID : 1554
Date and Time : Wed Jan 29 04:21:09 2014
Category : Instrumentation Service
Description : Log size is full
Log type: ESM

Severity : Non-Critical
ID : 1553
Date and Time : Wed Jan 29 03:07:37 2014
Category : Instrumentation Service
Description : Log size is near or at capacity
Log type: ESM

Severity : Ok
ID : 1552
Date and Time : Tue Jan 28 17:54:13 2014
Category : Instrumentation Service
Description : Log size is no longer near or at capacity
Log type: ESM

Severity : Ok
ID : 2124
Date and Time : Mon Jan 27 17:26:38 2014
Category : Storage Service
Description : Redundancy normal: Virtual Disk 0 (PERC H700 Integrated) Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2121
Date and Time : Mon Jan 27 17:26:38 2014
Category : Storage Service
Description : Device returned to normal: Virtual Disk 1 (PERC H700 Integrated) Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2124
Date and Time : Mon Jan 27 17:26:38 2014
Category : Storage Service
Description : Redundancy normal: Virtual Disk 1 (PERC H700 Integrated) Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2092
Date and Time : Mon Jan 27 17:26:37 2014
Category : Storage Service
Description : Physical disk Rebuild completed: Physical Disk 0:1 Controller 0, Connector 0

Severity : Ok
ID : 2158
Date and Time : Mon Jan 27 17:26:37 2014
Category : Storage Service
Description : Physical disk online: Physical Disk 0:1 Controller 0, Connector 0

Severity : Ok
ID : 2121
Date and Time : Mon Jan 27 17:26:37 2014
Category : Storage Service
Description : Device returned to normal: Virtual Disk 0 (PERC H700 Integrated) Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2358
Date and Time : Mon Jan 27 13:38:17 2014
Category : Storage Service
Description : The battery charge cycle is complete.: Battery 0 Controller 0

Severity : Ok
ID : 2334
Date and Time : Mon Jan 27 12:25:03 2014
Category : Storage Service
Description : Controller event log: Unexpected sense: Encl PD 20 Path 5942b0b05992f600, CDB: 1c 01 a0 00 04 00, Sense: 5/24/00: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Jan 27 12:25:03 2014
Category : Storage Service
Description : Controller event log: Unexpected sense: Encl PD 20 Path 5942b0b05992f600, CDB: 1c 01 a0 00 04 00, Sense: 5/24/00: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Jan 27 12:25:02 2014
Category : Storage Service
Description : Controller event log: Battery started charging: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Jan 27 12:25:02 2014
Category : Storage Service
Description : Controller event log: Unexpected sense: PD 01(e0xff/s1) Path 50000c0f01d92396, CDB: 12 01 dc 01 1d 00, Sense: 5/24/00: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Jan 27 12:25:02 2014
Category : Storage Service
Description : Controller event log: Unexpected sense: Encl PD 20 Path 5942b0b05992f600, CDB: 1c 01 a0 00 04 00, Sense: 5/24/00: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Jan 27 12:25:02 2014
Category : Storage Service
Description : Controller event log: Unexpected sense: Encl PD 20 Path 5942b0b05992f600, CDB: 1c 01 a0 00 04 00, Sense: 5/24/00: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Jan 27 12:25:01 2014
Category : Storage Service
Description : Controller event log: State change on PD 01(e0xff/s1) from OFFLINE(10) to REBUILD(14): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Jan 27 12:25:01 2014
Category : Storage Service
Description : Controller event log: Time established as 01/27/14 12:20:47; (63 seconds since power on): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Jan 27 12:25:01 2014
Category : Storage Service
Description : Controller event log: Battery temperature is normal: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Jan 27 12:25:01 2014
Category : Storage Service
Description : Controller event log: Current capacity of the battery is above threshold: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Jan 27 12:25:00 2014
Category : Storage Service
Description : Controller event log: Inserted: PD 04(e0x20/s4): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Jan 27 12:25:00 2014
Category : Storage Service
Description : Controller event log: Inserted: PD 05(e0x20/s5): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Jan 27 12:25:00 2014
Category : Storage Service
Description : Controller event log: State change on PD 01(e0xff/s1) from REBUILD(14) to OFFLINE(10): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Jan 27 12:25:00 2014
Category : Storage Service
Description : Controller event log: Rebuild resumed on PD 01(e0xff/s1): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Jan 27 12:24:59 2014
Category : Storage Service
Description : Controller event log: Inserted: PD 01(e0xff/s1): Controller 0 (PERC H700 Integrated)

Severity : Non-Critical
ID : 2335
Date and Time : Mon Jan 27 12:24:59 2014
Category : Storage Service
Description : Controller event log: PD 01(e0xff/s1) is not a certified drive: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Jan 27 12:24:59 2014
Category : Storage Service
Description : Controller event log: Inserted: PD 02(e0x20/s2): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Jan 27 12:24:59 2014
Category : Storage Service
Description : Controller event log: Inserted: PD 03(e0x20/s3): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Jan 27 12:24:58 2014
Category : Storage Service
Description : Controller event log: Board Revision A03: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Jan 27 12:24:58 2014
Category : Storage Service
Description : Controller event log: Enclosure PD 20(c None/p0) communication restored: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Jan 27 12:24:58 2014
Category : Storage Service
Description : Controller event log: Inserted: Encl PD 20: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Jan 27 12:24:58 2014
Category : Storage Service
Description : Controller event log: Inserted: PD 00(e0x20/s0): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Jan 27 12:24:57 2014
Category : Storage Service
Description : Controller event log: Shutdown command received from host: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Jan 27 12:24:57 2014
Category : Storage Service
Description : Controller event log: Firmware initialization started (PCI ID 0079/1000/1f17/1028): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Jan 27 12:24:57 2014
Category : Storage Service
Description : Controller event log: Battery Present: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Jan 27 12:24:57 2014
Category : Storage Service
Description : Controller event log: Package version 12.10.6-0001: Controller 0 (PERC H700 Integrated)

Severity : Critical
ID : 1554
Date and Time : Mon Jan 27 12:23:10 2014
Category : Instrumentation Service
Description : Log size is full
Log type: ESM

Severity : Non-Critical
ID : 2057
Date and Time : Mon Jan 27 12:22:53 2014
Category : Storage Service
Description : Virtual disk degraded: Virtual Disk 0 (PERC H700 Integrated) Controller 0 (PERC H700 Integrated)

Severity : Non-Critical
ID : 2057
Date and Time : Mon Jan 27 12:22:53 2014
Category : Storage Service
Description : Virtual disk degraded: Virtual Disk 1 (PERC H700 Integrated) Controller 0 (PERC H700 Integrated)

Severity : Non-Critical
ID : 2359
Date and Time : Mon Jan 27 12:22:52 2014
Category : Storage Service
Description : Disk found is not supplied by an authorized hardware provider: Physical Disk 0:1 Controller 0, Connector 0

Severity : Ok
ID : 1012
Date and Time : Mon Jan 27 12:22:47 2014
Category : Instrumentation Service
Description : IPMI status
Interface: User

Severity : Ok
ID : 1001
Date and Time : Mon Jan 27 12:22:47 2014
Category : Instrumentation Service
Description : Server Administrator startup complete

Severity : Ok
ID : 1008
Date and Time : Mon Jan 27 12:22:47 2014
Category : Instrumentation Service
Description : Systems Management Data Manager Started

Severity : Ok
ID : 1000
Date and Time : Mon Jan 27 12:22:46 2014
Category : Instrumentation Service
Description : Server Administrator starting

Severity : Non-Critical
ID : 2050
Date and Time : Mon Jan 27 12:00:53 2014
Category : Storage Service
Description : Physical disk offline: Physical Disk 0:1 Controller 0, Connector 0

Severity : Ok
ID : 2065
Date and Time : Mon Jan 27 12:00:53 2014
Category : Storage Service
Description : Physical disk Rebuild started: Physical Disk 0:1 Controller 0, Connector 0

Severity : Ok
ID : 2121
Date and Time : Mon Jan 27 12:00:53 2014
Category : Storage Service
Description : Device returned to normal: Physical Disk 0:1 Controller 0, Connector 0

Severity : Ok
ID : 2052
Date and Time : Mon Jan 27 12:00:52 2014
Category : Storage Service
Description : Physical device inserted: Physical Disk 0:1 Controller 0, Connector 0

Severity : Non-Critical
ID : 2359
Date and Time : Mon Jan 27 12:00:52 2014
Category : Storage Service
Description : Disk found is not supplied by an authorized hardware provider: Physical Disk 0:1 Controller 0, Connector 0

Severity : Ok
ID : 2121
Date and Time : Mon Jan 27 12:00:52 2014
Category : Storage Service
Description : Device returned to normal: Physical Disk 0:1 Controller 0, Connector 0

Severity : Non-Critical
ID : 2049
Date and Time : Mon Jan 27 11:53:54 2014
Category : Storage Service
Description : Physical device removed: Physical Disk 0:0:1 Controller 0, Connector 0

Severity : Critical
ID : 2048
Date and Time : Mon Jan 27 11:53:54 2014
Category : Storage Service
Description : Device failed: Physical Disk 0:1 Controller 0, Connector 0

Severity : Critical
ID : 1554
Date and Time : Mon Jan 27 09:36:52 2014
Category : Instrumentation Service
Description : Log size is full
Log type: ESM

Severity : Non-Critical
ID : 1553
Date and Time : Mon Jan 27 05:03:46 2014
Category : Instrumentation Service
Description : Log size is near or at capacity
Log type: ESM

Severity : Ok
ID : 2243
Date and Time : Sat Jan 25 18:28:18 2014
Category : Storage Service
Description : The Patrol Read has stopped.: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2242
Date and Time : Sat Jan 25 03:14:24 2014
Category : Storage Service
Description : The Patrol Read has started.: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 1552
Date and Time : Wed Jan 22 13:06:39 2014
Category : Instrumentation Service
Description : Log size is no longer near or at capacity
Log type: ESM

Severity : Critical
ID : 1554
Date and Time : Tue Jan 21 14:20:38 2014
Category : Instrumentation Service
Description : Log size is full
Log type: ESM

Severity : Non-Critical
ID : 1553
Date and Time : Tue Jan 21 04:09:10 2014
Category : Instrumentation Service
Description : Log size is near or at capacity
Log type: ESM

Severity : Ok
ID : 1552
Date and Time : Mon Jan 20 08:57:26 2014
Category : Instrumentation Service
Description : Log size is no longer near or at capacity
Log type: ESM

Severity : Ok
ID : 2243
Date and Time : Sat Jan 18 20:06:32 2014
Category : Storage Service
Description : The Patrol Read has stopped.: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2242
Date and Time : Sat Jan 18 03:14:19 2014
Category : Storage Service
Description : The Patrol Read has started.: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2358
Date and Time : Sun Jan 12 04:26:59 2014
Category : Storage Service
Description : The battery charge cycle is complete.: Battery 0 Controller 0

Severity : Ok
ID : 2189
Date and Time : Sun Jan 12 02:26:44 2014
Category : Storage Service
Description : The controller write policy has been changed to Write Back.: Battery 0 Controller 0

Severity : Ok
ID : 2199
Date and Time : Sun Jan 12 02:26:44 2014
Category : Storage Service
Description : The virtual disk cache policy has changed.: Virtual Disk 0 (PERC H700 Integrated) Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2199
Date and Time : Sun Jan 12 02:26:44 2014
Category : Storage Service
Description : The virtual disk cache policy has changed.: Virtual Disk 1 (PERC H700 Integrated) Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2247
Date and Time : Sun Jan 12 00:29:43 2014
Category : Storage Service
Description : The controller battery is charging.: Battery 0 Controller 0

Severity : Ok
ID : 2177
Date and Time : Sun Jan 12 00:29:28 2014
Category : Storage Service
Description : The controller battery Learn cycle has completed.: Battery 0 Controller 0

Severity : Ok
ID : 2188
Date and Time : Sat Jan 11 22:24:01 2014
Category : Storage Service
Description : The controller write policy has been changed to Write Through.: Battery 0 Controller 0

Severity : Ok
ID : 2199
Date and Time : Sat Jan 11 22:24:01 2014
Category : Storage Service
Description : The virtual disk cache policy has changed.: Virtual Disk 0 (PERC H700 Integrated) Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2199
Date and Time : Sat Jan 11 22:24:01 2014
Category : Storage Service
Description : The virtual disk cache policy has changed.: Virtual Disk 1 (PERC H700 Integrated) Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2176
Date and Time : Sat Jan 11 22:17:38 2014
Category : Storage Service
Description : The controller battery Learn cycle has started.: Battery 0 Controller 0

Severity : Ok
ID : 2243
Date and Time : Sat Jan 11 18:42:22 2014
Category : Storage Service
Description : The Patrol Read has stopped.: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2242
Date and Time : Sat Jan 11 03:14:13 2014
Category : Storage Service
Description : The Patrol Read has started.: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2180
Date and Time : Tue Jan 07 21:59:06 2014
Category : Storage Service
Description : The controller battery Learn cycle will start in 4 days.: Battery 0 Controller 0

Severity : Ok
ID : 2243
Date and Time : Sat Jan 04 17:04:34 2014
Category : Storage Service
Description : The Patrol Read has stopped.: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2242
Date and Time : Sat Jan 04 03:14:08 2014
Category : Storage Service
Description : The Patrol Read has started.: Controller 0 (PERC H700 Integrated)

Severity : Critical
ID : 1554
Date and Time : Thu Jan 02 14:20:58 2014
Category : Instrumentation Service
Description : Log size is full
Log type: ESM

Severity : Non-Critical
ID : 1553
Date and Time : Thu Jan 02 10:06:26 2014
Category : Instrumentation Service
Description : Log size is near or at capacity
Log type: ESM

Severity : Ok
ID : 1552
Date and Time : Mon Dec 30 12:45:30 2013
Category : Instrumentation Service
Description : Log size is no longer near or at capacity
Log type: ESM

Severity : Ok
ID : 2243
Date and Time : Sat Dec 28 20:05:52 2013
Category : Storage Service
Description : The Patrol Read has stopped.: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2242
Date and Time : Sat Dec 28 03:14:03 2013
Category : Storage Service
Description : The Patrol Read has started.: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2243
Date and Time : Sat Dec 21 18:08:41 2013
Category : Storage Service
Description : The Patrol Read has stopped.: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2242
Date and Time : Sat Dec 21 03:13:58 2013
Category : Storage Service
Description : The Patrol Read has started.: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2052
Date and Time : Fri Dec 20 14:42:30 2013
Category : Storage Service
Description : Physical device inserted: Physical Disk 0:0:1 Controller 0, Connector 0

Severity : Ok
ID : 2121
Date and Time : Fri Dec 20 14:42:30 2013
Category : Storage Service
Description : Device returned to normal: Physical Disk 0:0:1 Controller 0, Connector 0

Severity : Ok
ID : 2326
Date and Time : Fri Dec 20 14:42:30 2013
Category : Storage Service
Description : A foreign configuration has been detected.: Controller 0 (PERC H700 Integrated)

Severity : Critical
ID : 2048
Date and Time : Fri Dec 20 14:41:27 2013
Category : Storage Service
Description : Device failed: Physical Disk 0:0:1 Controller 0, Connector 0

Severity : Non-Critical
ID : 2123
Date and Time : Fri Dec 20 14:41:27 2013
Category : Storage Service
Description : Redundancy lost: Virtual Disk 0 (PERC H700 Integrated) Controller 0 (PERC H700 Integrated)

Severity : Non-Critical
ID : 2057
Date and Time : Fri Dec 20 14:41:27 2013
Category : Storage Service
Description : Virtual disk degraded: Virtual Disk 0 (PERC H700 Integrated) Controller 0 (PERC H700 Integrated)

Severity : Non-Critical
ID : 2123
Date and Time : Fri Dec 20 14:41:27 2013
Category : Storage Service
Description : Redundancy lost: Virtual Disk 1 (PERC H700 Integrated) Controller 0 (PERC H700 Integrated)

Severity : Non-Critical
ID : 2057
Date and Time : Fri Dec 20 14:41:27 2013
Category : Storage Service
Description : Virtual disk degraded: Virtual Disk 1 (PERC H700 Integrated) Controller 0 (PERC H700 Integrated)

Severity : Non-Critical
ID : 2049
Date and Time : Fri Dec 20 14:41:26 2013
Category : Storage Service
Description : Physical device removed: Physical Disk 0:0:1 Controller 0, Connector 0

Severity : Ok
ID : 1252
Date and Time : Fri Dec 20 14:40:53 2013
Category : Instrumentation Service
Description : Chassis intrusion returned to normal
Sensor location:
Chassis location: Main System Chassis
Previous state was: Critical (Failed)
Chassis intrusion state: Closed

Severity : Critical
ID : 1254
Date and Time : Fri Dec 20 14:40:30 2013
Category : Instrumentation Service
Description : Chassis intrusion detected
Sensor location:
Chassis location: Main System Chassis
Previous state was: OK (Normal)
Chassis intrusion state: Open

Severity : Critical
ID : 1554
Date and Time : Thu Dec 19 13:10:15 2013
Category : Instrumentation Service
Description : Log size is full
Log type: ESM

Severity : Non-Critical
ID : 1553
Date and Time : Thu Dec 19 11:24:15 2013
Category : Instrumentation Service
Description : Log size is near or at capacity
Log type: ESM

Severity : Ok
ID : 1552
Date and Time : Wed Dec 18 10:45:22 2013
Category : Instrumentation Service
Description : Log size is no longer near or at capacity
Log type: ESM

Severity : Critical
ID : 1554
Date and Time : Wed Dec 18 07:45:05 2013
Category : Instrumentation Service
Description : Log size is full
Log type: ESM

Severity : Non-Critical
ID : 1553
Date and Time : Tue Dec 17 21:50:16 2013
Category : Instrumentation Service
Description : Log size is near or at capacity
Log type: ESM

Severity : Ok
ID : 1552
Date and Time : Mon Dec 16 15:37:51 2013
Category : Instrumentation Service
Description : Log size is no longer near or at capacity
Log type: ESM

Severity : Critical
ID : 1554
Date and Time : Sun Dec 15 09:20:52 2013
Category : Instrumentation Service
Description : Log size is full
Log type: ESM

Severity : Non-Critical
ID : 1553
Date and Time : Sun Dec 15 04:04:38 2013
Category : Instrumentation Service
Description : Log size is near or at capacity
Log type: ESM

Severity : Ok
ID : 2243
Date and Time : Sat Dec 14 08:52:44 2013
Category : Storage Service
Description : The Patrol Read has stopped.: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2242
Date and Time : Sat Dec 14 03:13:53 2013
Category : Storage Service
Description : The Patrol Read has started.: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2243
Date and Time : Sat Dec 07 08:54:58 2013
Category : Storage Service
Description : The Patrol Read has stopped.: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2242
Date and Time : Sat Dec 07 03:13:48 2013
Category : Storage Service
Description : The Patrol Read has started.: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2243
Date and Time : Sat Nov 30 08:54:57 2013
Category : Storage Service
Description : The Patrol Read has stopped.: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2242
Date and Time : Sat Nov 30 03:13:43 2013
Category : Storage Service
Description : The Patrol Read has started.: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2243
Date and Time : Sat Nov 23 08:56:16 2013
Category : Storage Service
Description : The Patrol Read has stopped.: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2242
Date and Time : Sat Nov 23 03:13:38 2013
Category : Storage Service
Description : The Patrol Read has started.: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2243
Date and Time : Sat Nov 16 08:50:42 2013
Category : Storage Service
Description : The Patrol Read has stopped.: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2242
Date and Time : Sat Nov 16 03:13:33 2013
Category : Storage Service
Description : The Patrol Read has started.: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 1552
Date and Time : Wed Nov 13 08:21:00 2013
Category : Instrumentation Service
Description : Log size is no longer near or at capacity
Log type: ESM

Severity : Ok
ID : 2243
Date and Time : Sat Nov 09 08:51:58 2013
Category : Storage Service
Description : The Patrol Read has stopped.: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2242
Date and Time : Sat Nov 09 03:13:29 2013
Category : Storage Service
Description : The Patrol Read has started.: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2243
Date and Time : Sat Nov 02 08:49:47 2013
Category : Storage Service
Description : The Patrol Read has stopped.: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2242
Date and Time : Sat Nov 02 03:13:23 2013
Category : Storage Service
Description : The Patrol Read has started.: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2243
Date and Time : Sat Oct 26 09:46:09 2013
Category : Storage Service
Description : The Patrol Read has stopped.: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2242
Date and Time : Sat Oct 26 04:13:18 2013
Category : Storage Service
Description : The Patrol Read has started.: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2358
Date and Time : Thu Oct 24 15:10:31 2013
Category : Storage Service
Description : The battery charge cycle is complete.: Battery 0 Controller 0

Severity : Ok
ID : 2247
Date and Time : Thu Oct 24 14:23:56 2013
Category : Storage Service
Description : The controller battery is charging.: Battery 0 Controller 0

Severity : Critical
ID : 1554
Date and Time : Mon Oct 21 21:21:02 2013
Category : Instrumentation Service
Description : Log size is full
Log type: ESM

Severity : Non-Critical
ID : 1553
Date and Time : Mon Oct 21 18:19:58 2013
Category : Instrumentation Service
Description : Log size is near or at capacity
Log type: ESM

Severity : Ok
ID : 2243
Date and Time : Sat Oct 19 09:42:51 2013
Category : Storage Service
Description : The Patrol Read has stopped.: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2242
Date and Time : Sat Oct 19 04:13:12 2013
Category : Storage Service
Description : The Patrol Read has started.: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2130
Date and Time : Thu Oct 17 07:54:07 2013
Category : Storage Service
Description : Background Initialization completed: Virtual Disk 1 (PERC H700 Integrated) Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 17:39:17 2013
Category : Storage Service
Description : Controller event log: Unexpected sense: Encl PD 20 Path 5942b0b05992f600, CDB: 1c 01 a0 00 04 00, Sense: 5/24/00: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 17:39:17 2013
Category : Storage Service
Description : Controller event log: Unexpected sense: Encl PD 20 Path 5942b0b05992f600, CDB: 1c 01 a0 00 04 00, Sense: 5/24/00: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 17:39:16 2013
Category : Storage Service
Description : Controller event log: Current capacity of the battery is above threshold: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 17:39:16 2013
Category : Storage Service
Description : Controller event log: Battery charge complete: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 17:39:16 2013
Category : Storage Service
Description : Controller event log: Unexpected sense: Encl PD 20 Path 5942b0b05992f600, CDB: 1c 01 a0 00 04 00, Sense: 5/24/00: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 17:39:16 2013
Category : Storage Service
Description : Controller event log: Unexpected sense: Encl PD 20 Path 5942b0b05992f600, CDB: 1c 01 a0 00 04 00, Sense: 5/24/00: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 17:39:15 2013
Category : Storage Service
Description : Controller event log: Inserted: PD 05(e0x20/s5): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 17:39:15 2013
Category : Storage Service
Description : Controller event log: Background Initialization started on VD 01/1: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 17:39:15 2013
Category : Storage Service
Description : Controller event log: Time established as 10/15/13 17:37:12; (63 seconds since power on): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 17:39:15 2013
Category : Storage Service
Description : Controller event log: Battery temperature is normal: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 17:39:14 2013
Category : Storage Service
Description : Controller event log: Inserted: PD 01(e0x20/s1): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 17:39:14 2013
Category : Storage Service
Description : Controller event log: Inserted: PD 02(e0x20/s2): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 17:39:14 2013
Category : Storage Service
Description : Controller event log: Inserted: PD 03(e0x20/s3): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 17:39:14 2013
Category : Storage Service
Description : Controller event log: Inserted: PD 04(e0x20/s4): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 17:39:13 2013
Category : Storage Service
Description : Controller event log: Board Revision A03: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 17:39:13 2013
Category : Storage Service
Description : Controller event log: Enclosure PD 20(c None/p0) communication restored: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 17:39:13 2013
Category : Storage Service
Description : Controller event log: Inserted: Encl PD 20: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 17:39:13 2013
Category : Storage Service
Description : Controller event log: Inserted: PD 00(e0x20/s0): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 17:39:12 2013
Category : Storage Service
Description : Controller event log: Shutdown command received from host: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 17:39:12 2013
Category : Storage Service
Description : Controller event log: Firmware initialization started (PCI ID 0079/1000/1f17/1028): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 17:39:12 2013
Category : Storage Service
Description : Controller event log: Battery Present: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 17:39:12 2013
Category : Storage Service
Description : Controller event log: Package version 12.10.6-0001: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 1000
Date and Time : Tue Oct 15 17:39:06 2013
Category : Instrumentation Service
Description : Server Administrator starting

Severity : Ok
ID : 1012
Date and Time : Tue Oct 15 17:39:06 2013
Category : Instrumentation Service
Description : IPMI status
Interface: User

Severity : Ok
ID : 1001
Date and Time : Tue Oct 15 17:39:06 2013
Category : Instrumentation Service
Description : Server Administrator startup complete

Severity : Ok
ID : 1008
Date and Time : Tue Oct 15 17:39:06 2013
Category : Instrumentation Service
Description : Systems Management Data Manager Started

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 15:38:32 2013
Category : Storage Service
Description : Controller event log: Unexpected sense: Encl PD 20 Path 5942b0b05992f600, CDB: 1c 01 a0 00 04 00, Sense: 5/24/00: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 15:38:32 2013
Category : Storage Service
Description : Controller event log: Unexpected sense: Encl PD 20 Path 5942b0b05992f600, CDB: 1c 01 a0 00 04 00, Sense: 5/24/00: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 15:38:32 2013
Category : Storage Service
Description : Controller event log: Unexpected sense: Encl PD 20 Path 5942b0b05992f600, CDB: 1c 01 a0 00 04 00, Sense: 5/24/00: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 15:38:32 2013
Category : Storage Service
Description : Controller event log: Unexpected sense: Encl PD 20 Path 5942b0b05992f600, CDB: 1c 01 a0 00 04 00, Sense: 5/24/00: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 15:38:31 2013
Category : Storage Service
Description : Controller event log: Time established as 10/15/13 15:36:37; (63 seconds since power on): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 15:38:31 2013
Category : Storage Service
Description : Controller event log: Battery temperature is normal: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 15:38:31 2013
Category : Storage Service
Description : Controller event log: Current capacity of the battery is above threshold: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 15:38:31 2013
Category : Storage Service
Description : Controller event log: Battery charge complete: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 15:38:30 2013
Category : Storage Service
Description : Controller event log: Inserted: PD 03(e0x20/s3): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 15:38:30 2013
Category : Storage Service
Description : Controller event log: Inserted: PD 04(e0x20/s4): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 15:38:30 2013
Category : Storage Service
Description : Controller event log: Inserted: PD 05(e0x20/s5): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 15:38:30 2013
Category : Storage Service
Description : Controller event log: Background Initialization started on VD 01/1: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 15:38:29 2013
Category : Storage Service
Description : Controller event log: Inserted: Encl PD 20: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 15:38:29 2013
Category : Storage Service
Description : Controller event log: Inserted: PD 00(e0x20/s0): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 15:38:29 2013
Category : Storage Service
Description : Controller event log: Inserted: PD 01(e0x20/s1): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 15:38:29 2013
Category : Storage Service
Description : Controller event log: Inserted: PD 02(e0x20/s2): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 15:38:28 2013
Category : Storage Service
Description : Controller event log: Battery Present: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 15:38:28 2013
Category : Storage Service
Description : Controller event log: Package version 12.10.6-0001: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 15:38:28 2013
Category : Storage Service
Description : Controller event log: Board Revision A03: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 15:38:28 2013
Category : Storage Service
Description : Controller event log: Enclosure PD 20(c None/p0) communication restored: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 15:38:27 2013
Category : Storage Service
Description : Controller event log: Shutdown command received from host: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 15:38:27 2013
Category : Storage Service
Description : Controller event log: Firmware initialization started (PCI ID 0079/1000/1f17/1028): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 1000
Date and Time : Tue Oct 15 15:38:21 2013
Category : Instrumentation Service
Description : Server Administrator starting

Severity : Ok
ID : 1012
Date and Time : Tue Oct 15 15:38:21 2013
Category : Instrumentation Service
Description : IPMI status
Interface: User

Severity : Ok
ID : 1001
Date and Time : Tue Oct 15 15:38:21 2013
Category : Instrumentation Service
Description : Server Administrator startup complete

Severity : Ok
ID : 1008
Date and Time : Tue Oct 15 15:38:21 2013
Category : Instrumentation Service
Description : Systems Management Data Manager Started

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 15:33:08 2013
Category : Storage Service
Description : Controller event log: Unexpected sense: Encl PD 20 Path 5942b0b05992f600, CDB: 1c 01 a0 00 04 00, Sense: 5/24/00: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 15:33:08 2013
Category : Storage Service
Description : Controller event log: Unexpected sense: Encl PD 20 Path 5942b0b05992f600, CDB: 1c 01 a0 00 04 00, Sense: 5/24/00: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 15:33:08 2013
Category : Storage Service
Description : Controller event log: Unexpected sense: Encl PD 20 Path 5942b0b05992f600, CDB: 1c 01 a0 00 04 00, Sense: 5/24/00: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 15:33:07 2013
Category : Storage Service
Description : Controller event log: Battery temperature is normal: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 15:33:07 2013
Category : Storage Service
Description : Controller event log: Current capacity of the battery is above threshold: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 15:33:07 2013
Category : Storage Service
Description : Controller event log: Battery charge complete: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 15:33:07 2013
Category : Storage Service
Description : Controller event log: Unexpected sense: Encl PD 20 Path 5942b0b05992f600, CDB: 1c 01 a0 00 04 00, Sense: 5/24/00: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 15:33:06 2013
Category : Storage Service
Description : Controller event log: Inserted: PD 04(e0x20/s4): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 15:33:06 2013
Category : Storage Service
Description : Controller event log: Inserted: PD 05(e0x20/s5): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 15:33:06 2013
Category : Storage Service
Description : Controller event log: Background Initialization started on VD 01/1: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 15:33:06 2013
Category : Storage Service
Description : Controller event log: Time established as 10/15/13 15:31:08; (63 seconds since power on): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 15:33:05 2013
Category : Storage Service
Description : Controller event log: Inserted: PD 00(e0x20/s0): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 15:33:05 2013
Category : Storage Service
Description : Controller event log: Inserted: PD 01(e0x20/s1): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 15:33:05 2013
Category : Storage Service
Description : Controller event log: Inserted: PD 02(e0x20/s2): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 15:33:05 2013
Category : Storage Service
Description : Controller event log: Inserted: PD 03(e0x20/s3): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 15:33:04 2013
Category : Storage Service
Description : Controller event log: Package version 12.10.6-0001: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 15:33:04 2013
Category : Storage Service
Description : Controller event log: Board Revision A03: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 15:33:04 2013
Category : Storage Service
Description : Controller event log: Enclosure PD 20(c None/p0) communication restored: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 15:33:04 2013
Category : Storage Service
Description : Controller event log: Inserted: Encl PD 20: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 15:33:03 2013
Category : Storage Service
Description : Controller event log: Shutdown command received from host: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 15:33:03 2013
Category : Storage Service
Description : Controller event log: Firmware initialization started (PCI ID 0079/1000/1f17/1028): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 15:33:03 2013
Category : Storage Service
Description : Controller event log: Battery Present: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 1000
Date and Time : Tue Oct 15 15:32:57 2013
Category : Instrumentation Service
Description : Server Administrator starting

Severity : Ok
ID : 1012
Date and Time : Tue Oct 15 15:32:57 2013
Category : Instrumentation Service
Description : IPMI status
Interface: User

Severity : Ok
ID : 1001
Date and Time : Tue Oct 15 15:32:57 2013
Category : Instrumentation Service
Description : Server Administrator startup complete

Severity : Ok
ID : 1008
Date and Time : Tue Oct 15 15:32:57 2013
Category : Instrumentation Service
Description : Systems Management Data Manager Started

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 12:06:22 2013
Category : Storage Service
Description : Controller event log: Unexpected sense: Encl PD 20 Path 5942b0b05992f600, CDB: 1c 01 a0 00 04 00, Sense: 5/24/00: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 12:06:22 2013
Category : Storage Service
Description : Controller event log: Unexpected sense: Encl PD 20 Path 5942b0b05992f600, CDB: 1c 01 a0 00 04 00, Sense: 5/24/00: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 12:06:22 2013
Category : Storage Service
Description : Controller event log: Unexpected sense: Encl PD 20 Path 5942b0b05992f600, CDB: 1c 01 a0 00 04 00, Sense: 5/24/00: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 12:06:22 2013
Category : Storage Service
Description : Controller event log: Unexpected sense: Encl PD 20 Path 5942b0b05992f600, CDB: 1c 01 a0 00 04 00, Sense: 5/24/00: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 1000
Date and Time : Tue Oct 15 12:06:17 2013
Category : Instrumentation Service
Description : Server Administrator starting

Severity : Ok
ID : 1012
Date and Time : Tue Oct 15 12:06:17 2013
Category : Instrumentation Service
Description : IPMI status
Interface: User

Severity : Ok
ID : 1001
Date and Time : Tue Oct 15 12:06:17 2013
Category : Instrumentation Service
Description : Server Administrator startup complete

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 11:53:37 2013
Category : Storage Service
Description : Controller event log: Battery charge complete: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 11:53:36 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 01/1 is 25.92%(4188s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 11:53:36 2013
Category : Storage Service
Description : Controller event log: Time established as 10/15/13 11:51:49; (63 seconds since power on): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 11:53:36 2013
Category : Storage Service
Description : Controller event log: Battery temperature is normal: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 11:53:36 2013
Category : Storage Service
Description : Controller event log: Current capacity of the battery is above threshold: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 11:53:35 2013
Category : Storage Service
Description : Controller event log: Inserted: PD 03(e0x20/s3): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 11:53:35 2013
Category : Storage Service
Description : Controller event log: Inserted: PD 04(e0x20/s4): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 11:53:35 2013
Category : Storage Service
Description : Controller event log: Inserted: PD 05(e0x20/s5): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 11:53:35 2013
Category : Storage Service
Description : Controller event log: Background Initialization started on VD 01/1: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 11:53:34 2013
Category : Storage Service
Description : Controller event log: Inserted: Encl PD 20: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 11:53:34 2013
Category : Storage Service
Description : Controller event log: Inserted: PD 00(e0x20/s0): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 11:53:34 2013
Category : Storage Service
Description : Controller event log: Inserted: PD 01(e0x20/s1): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 11:53:34 2013
Category : Storage Service
Description : Controller event log: Inserted: PD 02(e0x20/s2): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 11:53:33 2013
Category : Storage Service
Description : Controller event log: Battery Present: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 11:53:33 2013
Category : Storage Service
Description : Controller event log: Package version 12.10.6-0001: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 11:53:33 2013
Category : Storage Service
Description : Controller event log: Board Revision A03: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 11:53:33 2013
Category : Storage Service
Description : Controller event log: Enclosure PD 20(c None/p0) communication restored: Controller 0 (PERC H700 Integrated)

Severity : Non-Critical
ID : 2131
Date and Time : Tue Oct 15 11:53:32 2013
Category : Storage Service
Description : The current firmware version 12.10.6-0001 is older than the required firmware version 12.3.0-0032 for a controller of model 0x1F17: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 11:53:32 2013
Category : Storage Service
Description : Controller event log: Shutdown command received from host: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 11:53:32 2013
Category : Storage Service
Description : Controller event log: Firmware initialization started (PCI ID 0079/1000/1f17/1028): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 1000
Date and Time : Tue Oct 15 11:53:26 2013
Category : Instrumentation Service
Description : Server Administrator starting

Severity : Ok
ID : 1012
Date and Time : Tue Oct 15 11:53:26 2013
Category : Instrumentation Service
Description : IPMI status
Interface: User

Severity : Ok
ID : 1001
Date and Time : Tue Oct 15 11:53:26 2013
Category : Instrumentation Service
Description : Server Administrator startup complete

Severity : Ok
ID : 1008
Date and Time : Tue Oct 15 11:53:26 2013
Category : Instrumentation Service
Description : Systems Management Data Manager Started

Severity : Non-Critical
ID : 2335
Date and Time : Tue Oct 15 11:48:27 2013
Category : Storage Service
Description : Controller event log: Current capacity of the battery is below threshold: Controller 0 (PERC H700 Integrated)

Severity : Non-Critical
ID : 2335
Date and Time : Tue Oct 15 11:48:27 2013
Category : Storage Service
Description : Controller event log: BBU disabled; changing WB virtual disks to WT: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 11:48:27 2013
Category : Storage Service
Description : Controller event log: Policy change on VD 00/0 to [ID=00,dcp=0d,ccp=0c,ap=0,dc=0,dbgi=0,S=0|0] from [ID=00,dcp=0d,ccp=0d,ap=0,dc=0,dbgi=0,S=0|0]: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 11:48:27 2013
Category : Storage Service
Description : Controller event log: Policy change on VD 01/1 to [ID=01,dcp=0d,ccp=0c,ap=0,dc=0,dbgi=0,S=0|0] from [ID=01,dcp=0d,ccp=0d,ap=0,dc=0,dbgi=0,S=0|0]: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 11:48:27 2013
Category : Storage Service
Description : Controller event log: Time established as 10/15/13 11:46:23; (70 seconds since power on): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 11:48:27 2013
Category : Storage Service
Description : Controller event log: Battery charge complete: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 11:48:23 2013
Category : Storage Service
Description : Controller event log: Battery started charging: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 11:48:22 2013
Category : Storage Service
Description : Controller event log: Background Initialization started on VD 01/1: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 11:48:22 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 01/1 is 25.12%(527s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 11:48:22 2013
Category : Storage Service
Description : Controller event log: Battery temperature is normal: Controller 0 (PERC H700 Integrated)

Severity : Non-Critical
ID : 2335
Date and Time : Tue Oct 15 11:48:22 2013
Category : Storage Service
Description : Controller event log: Battery needs replacement - SOH Bad: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 11:48:21 2013
Category : Storage Service
Description : Controller event log: Inserted: PD 02(e0x20/s2): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 11:48:21 2013
Category : Storage Service
Description : Controller event log: Inserted: PD 03(e0x20/s3): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 11:48:21 2013
Category : Storage Service
Description : Controller event log: Inserted: PD 04(e0x20/s4): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 11:48:21 2013
Category : Storage Service
Description : Controller event log: Inserted: PD 05(e0x20/s5): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 11:48:20 2013
Category : Storage Service
Description : Controller event log: Enclosure PD 20(c None/p0) communication restored: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 11:48:20 2013
Category : Storage Service
Description : Controller event log: Inserted: Encl PD 20: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 11:48:20 2013
Category : Storage Service
Description : Controller event log: Inserted: PD 00(e0x20/s0): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 11:48:20 2013
Category : Storage Service
Description : Controller event log: Inserted: PD 01(e0x20/s1): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 11:48:19 2013
Category : Storage Service
Description : Controller event log: Battery Present: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 11:48:19 2013
Category : Storage Service
Description : Controller event log: Package version 12.3.0-0032: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 11:48:19 2013
Category : Storage Service
Description : Controller event log: Board Revision A03: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 11:48:19 2013
Category : Storage Service
Description : Controller event log: Unexpected sense: Encl PD 20 Path 5942b0b05992f600, CDB: 1c 01 00 00 20 00, Sense: 6/29/00: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 11:48:18 2013
Category : Storage Service
Description : Controller event log: Battery Present: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 11:48:18 2013
Category : Storage Service
Description : Controller event log: Package version 12.3.0-0032: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 11:48:18 2013
Category : Storage Service
Description : Controller event log: Board Revision A03: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 11:48:18 2013
Category : Storage Service
Description : Controller event log: Firmware initialization started (PCI ID 0079/1000/1f17/1028): Controller 0 (PERC H700 Integrated)

Severity : Critical
ID : 2169
Date and Time : Tue Oct 15 11:48:17 2013
Category : Storage Service
Description : The controller battery needs to be replaced.: Battery 0 Controller 0

Severity : Critical
ID : 2048
Date and Time : Tue Oct 15 11:48:17 2013
Category : Storage Service
Description : Device failed: Battery 0 Controller 0

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 11:48:17 2013
Category : Storage Service
Description : Controller event log: Shutdown command received from host: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 11:48:17 2013
Category : Storage Service
Description : Controller event log: Firmware initialization started (PCI ID 0079/1000/1f17/1028): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 1000
Date and Time : Tue Oct 15 11:48:12 2013
Category : Instrumentation Service
Description : Server Administrator starting

Severity : Ok
ID : 1012
Date and Time : Tue Oct 15 11:48:12 2013
Category : Instrumentation Service
Description : IPMI status
Interface: User

Severity : Ok
ID : 1001
Date and Time : Tue Oct 15 11:48:12 2013
Category : Instrumentation Service
Description : Server Administrator startup complete

Severity : Ok
ID : 1008
Date and Time : Tue Oct 15 11:48:12 2013
Category : Instrumentation Service
Description : Systems Management Data Manager Started

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 11:36:34 2013
Category : Storage Service
Description : Controller event log: Current capacity of the battery is above threshold: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 11:36:34 2013
Category : Storage Service
Description : Controller event log: Battery charge complete: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 11:36:31 2013
Category : Storage Service
Description : Controller event log: Time established as 10/15/13 11:34:46; (63 seconds since power on): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 11:36:31 2013
Category : Storage Service
Description : Controller event log: Battery temperature is normal: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 11:36:30 2013
Category : Storage Service
Description : Controller event log: Inserted: PD 04(e0x20/s4): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 11:36:30 2013
Category : Storage Service
Description : Controller event log: Inserted: PD 05(e0x20/s5): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 11:36:30 2013
Category : Storage Service
Description : Controller event log: Background Initialization started on VD 01/1: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 11:36:30 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 01/1 is 25.72%(3246s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 11:36:29 2013
Category : Storage Service
Description : Controller event log: Inserted: PD 00(e0x20/s0): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 11:36:29 2013
Category : Storage Service
Description : Controller event log: Inserted: PD 01(e0x20/s1): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 11:36:29 2013
Category : Storage Service
Description : Controller event log: Inserted: PD 02(e0x20/s2): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 11:36:29 2013
Category : Storage Service
Description : Controller event log: Inserted: PD 03(e0x20/s3): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 11:36:28 2013
Category : Storage Service
Description : Controller event log: Package version 12.10.6-0001: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 11:36:28 2013
Category : Storage Service
Description : Controller event log: Board Revision A03: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 11:36:28 2013
Category : Storage Service
Description : Controller event log: Enclosure PD 20(c None/p0) communication restored: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 11:36:28 2013
Category : Storage Service
Description : Controller event log: Inserted: Encl PD 20: Controller 0 (PERC H700 Integrated)

Severity : Non-Critical
ID : 2131
Date and Time : Tue Oct 15 11:36:27 2013
Category : Storage Service
Description : The current firmware version 12.10.6-0001 is older than the required firmware version 12.3.0-0032 for a controller of model 0x1F17: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 11:36:27 2013
Category : Storage Service
Description : Controller event log: Shutdown command received from host: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 11:36:27 2013
Category : Storage Service
Description : Controller event log: Firmware initialization started (PCI ID 0079/1000/1f17/1028): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 11:36:27 2013
Category : Storage Service
Description : Controller event log: Battery Present: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 1000
Date and Time : Tue Oct 15 11:36:21 2013
Category : Instrumentation Service
Description : Server Administrator starting

Severity : Ok
ID : 1012
Date and Time : Tue Oct 15 11:36:21 2013
Category : Instrumentation Service
Description : IPMI status
Interface: User

Severity : Ok
ID : 1001
Date and Time : Tue Oct 15 11:36:21 2013
Category : Instrumentation Service
Description : Server Administrator startup complete

Severity : Ok
ID : 1008
Date and Time : Tue Oct 15 11:36:21 2013
Category : Instrumentation Service
Description : Systems Management Data Manager Started

Severity : Ok
ID : 2266
Date and Time : Tue Oct 15 11:28:00 2013
Category : Storage Service
Description : Controller log file entry: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2199
Date and Time : Tue Oct 15 11:28:00 2013
Category : Storage Service
Description : The virtual disk cache policy has changed.: Virtual Disk 0 (Virtual Disk 0) Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2199
Date and Time : Tue Oct 15 11:28:00 2013
Category : Storage Service
Description : The virtual disk cache policy has changed.: Virtual Disk 1 (Virtual Disk 1) Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2266
Date and Time : Tue Oct 15 11:27:59 2013
Category : Storage Service
Description : Controller log file entry: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2266
Date and Time : Tue Oct 15 11:27:59 2013
Category : Storage Service
Description : Controller log file entry: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2266
Date and Time : Tue Oct 15 11:27:59 2013
Category : Storage Service
Description : Controller log file entry: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2266
Date and Time : Tue Oct 15 11:27:59 2013
Category : Storage Service
Description : Controller log file entry: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2266
Date and Time : Tue Oct 15 11:27:58 2013
Category : Storage Service
Description : Controller log file entry: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2266
Date and Time : Tue Oct 15 11:27:58 2013
Category : Storage Service
Description : Controller log file entry: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2266
Date and Time : Tue Oct 15 11:27:58 2013
Category : Storage Service
Description : Controller log file entry: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 1152
Date and Time : Tue Oct 15 11:06:28 2013
Category : Instrumentation Service
Description : Voltage sensor returned to a normal value
Sensor location: PS 2 Voltage
Chassis location: Main System Chassis
Previous state was: Unknown
Voltage sensor value (in Volts): 120.000

Severity : Ok
ID : 1152
Date and Time : Tue Oct 15 11:06:27 2013
Category : Instrumentation Service
Description : Voltage sensor returned to a normal value
Sensor location: PS 1 Voltage
Chassis location: Main System Chassis
Previous state was: Unknown
Voltage sensor value (in Volts): 120.000

Severity : Ok
ID : 1151
Date and Time : Tue Oct 15 11:04:54 2013
Category : Instrumentation Service
Description : Voltage sensor value unknown
Sensor location: PS 1 Voltage
Chassis location: Main System Chassis
Previous state was: OK (Normal)
Voltage sensor value (in Volts): 0.000

Severity : Ok
ID : 1151
Date and Time : Tue Oct 15 11:04:52 2013
Category : Instrumentation Service
Description : Voltage sensor value unknown
Sensor location: PS 2 Voltage
Chassis location: Main System Chassis
Previous state was: OK (Normal)
Voltage sensor value (in Volts): 0.000

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 09:28:25 2013
Category : Storage Service
Description : Controller event log: Policy change on VD 01/1 to [ID=01,dcp=0d,ccp=0c,ap=0,dc=0,dbgi=0,S=0|0] from [ID=01,dcp=0d,ccp=0d,ap=0,dc=0,dbgi=0,S=0|0]: Controller 0 (PERC H700 Integrated)

Severity : Non-Critical
ID : 2335
Date and Time : Tue Oct 15 09:28:24 2013
Category : Storage Service
Description : Controller event log: Battery needs replacement - SOH Bad: Controller 0 (PERC H700 Integrated)

Severity : Non-Critical
ID : 2335
Date and Time : Tue Oct 15 09:28:24 2013
Category : Storage Service
Description : Controller event log: Current capacity of the battery is below threshold: Controller 0 (PERC H700 Integrated)

Severity : Non-Critical
ID : 2335
Date and Time : Tue Oct 15 09:28:24 2013
Category : Storage Service
Description : Controller event log: BBU disabled; changing WB virtual disks to WT: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 09:28:24 2013
Category : Storage Service
Description : Controller event log: Policy change on VD 00/0 to [ID=00,dcp=0d,ccp=0c,ap=0,dc=0,dbgi=0,S=0|0] from [ID=00,dcp=0d,ccp=0d,ap=0,dc=0,dbgi=0,S=0|0]: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 09:28:23 2013
Category : Storage Service
Description : Controller event log: Background Initialization started on VD 01/1: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 09:28:23 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 01/1 is 23.29%(57819s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 09:28:23 2013
Category : Storage Service
Description : Controller event log: Time established as 10/15/13 9:26:35; (68 seconds since power on): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 09:28:23 2013
Category : Storage Service
Description : Controller event log: Battery temperature is normal: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 09:28:22 2013
Category : Storage Service
Description : Controller event log: Inserted: PD 02(e0x20/s2): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 09:28:22 2013
Category : Storage Service
Description : Controller event log: Inserted: PD 03(e0x20/s3): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 09:28:22 2013
Category : Storage Service
Description : Controller event log: Inserted: PD 04(e0x20/s4): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 09:28:22 2013
Category : Storage Service
Description : Controller event log: Inserted: PD 05(e0x20/s5): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 09:28:21 2013
Category : Storage Service
Description : Controller event log: Enclosure PD 20(c None/p0) communication restored: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 09:28:21 2013
Category : Storage Service
Description : Controller event log: Inserted: Encl PD 20: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 09:28:21 2013
Category : Storage Service
Description : Controller event log: Inserted: PD 00(e0x20/s0): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 09:28:21 2013
Category : Storage Service
Description : Controller event log: Inserted: PD 01(e0x20/s1): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 09:28:20 2013
Category : Storage Service
Description : Controller event log: Firmware initialization started (PCI ID 0079/1000/1f17/1028): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 09:28:20 2013
Category : Storage Service
Description : Controller event log: Battery Present: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 09:28:20 2013
Category : Storage Service
Description : Controller event log: Package version 12.3.0-0032: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 09:28:20 2013
Category : Storage Service
Description : Controller event log: Board Revision A03: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 09:28:19 2013
Category : Storage Service
Description : Controller event log: Firmware initialization started (PCI ID 0079/1000/1f17/1028): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 09:28:19 2013
Category : Storage Service
Description : Controller event log: Battery Present: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 09:28:19 2013
Category : Storage Service
Description : Controller event log: Package version 12.3.0-0032: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 09:28:19 2013
Category : Storage Service
Description : Controller event log: Board Revision A03: Controller 0 (PERC H700 Integrated)

Severity : Non-Critical
ID : 2335
Date and Time : Tue Oct 15 09:28:18 2013
Category : Storage Service
Description : Controller event log: Current capacity of the battery is below threshold: Controller 0 (PERC H700 Integrated)

Severity : Non-Critical
ID : 2335
Date and Time : Tue Oct 15 09:28:18 2013
Category : Storage Service
Description : Controller event log: BBU disabled; changing WB virtual disks to WT: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 09:28:18 2013
Category : Storage Service
Description : Controller event log: Policy change on VD 00/0 to [ID=00,dcp=0d,ccp=0c,ap=0,dc=0,dbgi=0,S=0|0] from [ID=00,dcp=0d,ccp=0d,ap=0,dc=0,dbgi=0,S=0|0]: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 09:28:18 2013
Category : Storage Service
Description : Controller event log: Policy change on VD 01/1 to [ID=01,dcp=0d,ccp=0c,ap=0,dc=0,dbgi=0,S=0|0] from [ID=01,dcp=0d,ccp=0d,ap=0,dc=0,dbgi=0,S=0|0]: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 09:28:17 2013
Category : Storage Service
Description : Controller event log: Time established as 10/15/13 9:23:30; (42 seconds since power on): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 09:28:17 2013
Category : Storage Service
Description : Controller event log: Battery temperature is normal: Controller 0 (PERC H700 Integrated)

Severity : Non-Critical
ID : 2335
Date and Time : Tue Oct 15 09:28:17 2013
Category : Storage Service
Description : Controller event log: Battery needs replacement - SOH Bad: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 09:28:17 2013
Category : Storage Service
Description : Controller event log: Battery started charging: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 09:28:16 2013
Category : Storage Service
Description : Controller event log: Inserted: PD 04(e0x20/s4): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 09:28:16 2013
Category : Storage Service
Description : Controller event log: Inserted: PD 05(e0x20/s5): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 09:28:16 2013
Category : Storage Service
Description : Controller event log: Background Initialization started on VD 01/1: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 09:28:16 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 01/1 is 23.27%(57721s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 09:28:15 2013
Category : Storage Service
Description : Controller event log: Inserted: Encl PD 20: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 09:28:15 2013
Category : Storage Service
Description : Controller event log: Inserted: PD 00(e0x20/s0): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 09:28:15 2013
Category : Storage Service
Description : Controller event log: Inserted: PD 01(e0x20/s1): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 09:28:15 2013
Category : Storage Service
Description : Controller event log: Inserted: PD 02(e0x20/s2): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 09:28:15 2013
Category : Storage Service
Description : Controller event log: Inserted: PD 03(e0x20/s3): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 09:28:14 2013
Category : Storage Service
Description : Controller event log: Package version 12.3.0-0032: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 09:28:14 2013
Category : Storage Service
Description : Controller event log: Board Revision A03: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 09:28:14 2013
Category : Storage Service
Description : Controller event log: Enclosure PD 20(c None/p0) communication restored: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 09:28:13 2013
Category : Storage Service
Description : Controller event log: Package version 12.3.0-0032: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 09:28:13 2013
Category : Storage Service
Description : Controller event log: Board Revision A03: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 09:28:13 2013
Category : Storage Service
Description : Controller event log: Firmware initialization started (PCI ID 0079/1000/1f17/1028): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 09:28:13 2013
Category : Storage Service
Description : Controller event log: Battery Present: Controller 0 (PERC H700 Integrated)

Severity : Critical
ID : 2048
Date and Time : Tue Oct 15 09:28:12 2013
Category : Storage Service
Description : Device failed: Battery 0 Controller 0

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 09:28:12 2013
Category : Storage Service
Description : Controller event log: Shutdown command received from host: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 09:28:12 2013
Category : Storage Service
Description : Controller event log: Firmware initialization started (PCI ID 0079/1000/1f17/1028): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Oct 15 09:28:12 2013
Category : Storage Service
Description : Controller event log: Battery Present: Controller 0 (PERC H700 Integrated)

Severity : Critical
ID : 2169
Date and Time : Tue Oct 15 09:28:11 2013
Category : Storage Service
Description : The controller battery needs to be replaced.: Battery 0 Controller 0

Severity : Ok
ID : 1000
Date and Time : Tue Oct 15 09:28:06 2013
Category : Instrumentation Service
Description : Server Administrator starting

Severity : Ok
ID : 1012
Date and Time : Tue Oct 15 09:28:06 2013
Category : Instrumentation Service
Description : IPMI status
Interface: User

Severity : Ok
ID : 1001
Date and Time : Tue Oct 15 09:28:06 2013
Category : Instrumentation Service
Description : Server Administrator startup complete

Severity : Ok
ID : 1008
Date and Time : Tue Oct 15 09:28:06 2013
Category : Instrumentation Service
Description : Systems Management Data Manager Started

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:40:05 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 01/1 is 9.94%(4575s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:40:05 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 01/1 is 10.19%(4613s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:40:05 2013
Category : Storage Service
Description : Controller event log: VD 00/0 Properties updated to [ID=00,dcp=0d,ccp=0c,ap=0,dc=0,dbgi=0,S=0|0] (from [ID=00,dcp=0d,ccp=0c,ap=0,dc=0,dbgi=0,S=0|0]): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:40:05 2013
Category : Storage Service
Description : Controller event log: VD 01/1 Properties updated to [ID=01,dcp=0d,ccp=0c,ap=0,dc=0,dbgi=0,S=0|0] (from [ID=01,dcp=0d,ccp=0c,ap=0,dc=0,dbgi=0,S=0|0]): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:40:04 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 01/1 is 9.20%(4467s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:40:04 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 01/1 is 9.45%(4503s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:40:04 2013
Category : Storage Service
Description : Controller event log: Battery charge complete: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:40:04 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 01/1 is 9.70%(4539s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:40:03 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 01/1 is 8.27%(4332s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:40:03 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 01/1 is 8.45%(4358s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:40:03 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 01/1 is 8.70%(4394s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:40:03 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 01/1 is 8.95%(4431s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:40:02 2013
Category : Storage Service
Description : Controller event log: Policy change on VD 00/0 to [ID=00,dcp=0d,ccp=0c,ap=0,dc=0,dbgi=0,S=0|0] from [ID=00,dcp=0d,ccp=0d,ap=0,dc=0,dbgi=0,S=0|0]: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:40:02 2013
Category : Storage Service
Description : Controller event log: Policy change on VD 01/1 to [ID=01,dcp=0d,ccp=0c,ap=0,dc=0,dbgi=0,S=0|0] from [ID=01,dcp=0d,ccp=0d,ap=0,dc=0,dbgi=0,S=0|0]: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:40:02 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 01/1 is 8.17%(4316s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:40:02 2013
Category : Storage Service
Description : Controller event log: Time established as 10/14/13 17:32:20; (74 seconds since power on): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:40:01 2013
Category : Storage Service
Description : Controller event log: Battery started charging: Controller 0 (PERC H700 Integrated)

Severity : Non-Critical
ID : 2335
Date and Time : Mon Oct 14 18:40:01 2013
Category : Storage Service
Description : Controller event log: Current capacity of the battery is below threshold: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:40:01 2013
Category : Storage Service
Description : Controller event log: Background Initialization started on VD 01/1: Controller 0 (PERC H700 Integrated)

Severity : Non-Critical
ID : 2335
Date and Time : Mon Oct 14 18:40:01 2013
Category : Storage Service
Description : Controller event log: BBU disabled; changing WB virtual disks to WT: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:40:00 2013
Category : Storage Service
Description : Controller event log: Inserted: PD 04(e0x20/s4): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:40:00 2013
Category : Storage Service
Description : Controller event log: Inserted: PD 05(e0x20/s5): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:40:00 2013
Category : Storage Service
Description : Controller event log: Battery temperature is normal: Controller 0 (PERC H700 Integrated)

Severity : Non-Critical
ID : 2335
Date and Time : Mon Oct 14 18:40:00 2013
Category : Storage Service
Description : Controller event log: Battery needs replacement - SOH Bad: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:59 2013
Category : Storage Service
Description : Controller event log: Inserted: PD 00(e0x20/s0): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:59 2013
Category : Storage Service
Description : Controller event log: Inserted: PD 01(e0x20/s1): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:59 2013
Category : Storage Service
Description : Controller event log: Inserted: PD 02(e0x20/s2): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:59 2013
Category : Storage Service
Description : Controller event log: Inserted: PD 03(e0x20/s3): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:58 2013
Category : Storage Service
Description : Controller event log: Package version 12.3.0-0032: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:58 2013
Category : Storage Service
Description : Controller event log: Board Revision A03: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:58 2013
Category : Storage Service
Description : Controller event log: Enclosure PD 20(c None/p0) communication restored: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:58 2013
Category : Storage Service
Description : Controller event log: Inserted: Encl PD 20: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:57 2013
Category : Storage Service
Description : Controller event log: Package version 12.3.0-0032: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:57 2013
Category : Storage Service
Description : Controller event log: Board Revision A03: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:57 2013
Category : Storage Service
Description : Controller event log: Firmware initialization started (PCI ID 0079/1000/1f17/1028): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:57 2013
Category : Storage Service
Description : Controller event log: Battery Present: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:56 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 01/1 is 7.71%(4247s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:56 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 01/1 is 7.95%(4283s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:56 2013
Category : Storage Service
Description : Controller event log: Firmware initialization started (PCI ID 0079/1000/1f17/1028): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:56 2013
Category : Storage Service
Description : Controller event log: Battery Present: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:55 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 01/1 is 6.71%(4102s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:55 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 01/1 is 6.96%(4138s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:55 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 01/1 is 7.21%(4175s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:55 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 01/1 is 7.46%(4211s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:54 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 01/1 is 5.72%(3957s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:54 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 01/1 is 5.96%(3993s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:54 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 01/1 is 6.21%(4029s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:54 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 01/1 is 6.46%(4066s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:53 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 01/1 is 4.72%(3812s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:53 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 01/1 is 4.97%(3848s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:53 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 01/1 is 5.22%(3884s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:53 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 01/1 is 5.47%(3921s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:52 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 01/1 is 3.73%(3317s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:52 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 01/1 is 3.97%(3487s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:52 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 01/1 is 4.22%(3647s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:52 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 01/1 is 4.47%(3777s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:51 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 01/1 is 2.73%(2697s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:51 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 01/1 is 2.98%(2851s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:51 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 01/1 is 3.23%(3007s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:51 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 01/1 is 3.48%(3159s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:50 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 01/1 is 1.74%(2059s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:50 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 01/1 is 1.98%(2215s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:50 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 01/1 is 2.23%(2375s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:50 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 01/1 is 2.48%(2543s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:49 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 99.43%(1633s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:49 2013
Category : Storage Service
Description : Controller event log: Background Initialization completed on VD 00/0: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:49 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 01/1 is 1.24%(1742s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:49 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 01/1 is 1.49%(1895s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:48 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 93.49%(1569s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:48 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 94.84%(1585s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:48 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 96.32%(1601s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:48 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 97.86%(1617s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:47 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 89.04%(1521s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:47 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 01/1 is 0.99%(1531s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:47 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 90.56%(1537s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:47 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 92.03%(1553s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:46 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 83.08%(1457s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:46 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 84.59%(1473s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:46 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 86.17%(1489s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:46 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 87.65%(1505s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:45 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 76.99%(1393s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:45 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 78.44%(1409s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:45 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 79.90%(1425s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:45 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 81.50%(1441s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:44 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 71.32%(1329s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:44 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 72.83%(1345s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:44 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 74.39%(1361s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:44 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 75.79%(1377s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:43 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 65.23%(1265s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:43 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 66.73%(1281s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:43 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 68.23%(1297s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:43 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 69.85%(1313s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:42 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 59.49%(1201s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:42 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 60.90%(1217s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:42 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 62.43%(1233s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:42 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 63.81%(1249s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:41 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 55.27%(1153s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:41 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 56.79%(1169s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:41 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 58.17%(1185s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:41 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 01/1 is 0.74%(1196s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:40 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 50.28%(1089s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:40 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 51.51%(1105s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:40 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 52.59%(1121s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:40 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 53.84%(1137s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:39 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 44.67%(1025s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:39 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 46.12%(1041s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:39 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 47.58%(1057s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:39 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 48.96%(1073s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:38 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 38.64%(961s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:38 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 40.11%(977s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:38 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 41.62%(993s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:38 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 43.21%(1009s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:37 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 33.15%(897s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:37 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 34.63%(913s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:37 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 35.88%(929s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:37 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 37.16%(945s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:36 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 28.11%(849s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:36 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 01/1 is 0.49%(849s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:36 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 29.77%(865s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:36 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 31.49%(881s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:35 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 26.12%(785s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:35 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 26.42%(801s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:35 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 26.70%(817s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:35 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 26.98%(833s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:34 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 25.01%(721s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:34 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 25.29%(737s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:34 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 25.58%(753s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:34 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 25.85%(769s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:33 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 23.93%(657s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:33 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 24.19%(673s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:33 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 24.47%(689s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:33 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 24.75%(705s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:32 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 22.78%(593s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:32 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 23.08%(609s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:32 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 23.37%(625s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:32 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 23.66%(641s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:31 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 01/1 is 0.24%(536s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:31 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 21.91%(545s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:31 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 22.20%(561s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:31 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 22.49%(577s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:30 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 20.79%(481s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:30 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 21.07%(497s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:30 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 21.36%(513s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:30 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 21.63%(529s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:29 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 19.62%(417s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:29 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 19.92%(433s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:29 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 20.22%(449s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:29 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 20.51%(465s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:28 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 18.44%(353s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:28 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 18.74%(369s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:28 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 19.03%(385s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:28 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 19.33%(401s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:27 2013
Category : Storage Service
Description : Controller event log: Unexpected sense: PD 00(e0x20/s0) Path 5000c5002135f7a9, CDB: 28 00 00 5b af 80 00 00 80 00, Sense: 3/11/00: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:27 2013
Category : Storage Service
Description : Controller event log: Background Initialization corrected medium error (VD 00/0 at 5bafcc, PD 00(e0x20/s0) at 5bafcc): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:27 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 17.91%(321s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:27 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 18.17%(337s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:26 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 16.83%(257s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:26 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 17.13%(273s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:26 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 17.43%(289s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:26 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 17.72%(305s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:25 2013
Category : Storage Service
Description : Controller event log: Background Initialization corrected medium error (VD 00/0 at 5349ca, PD 00(e0x20/s0) at 5349ca): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:25 2013
Category : Storage Service
Description : Controller event log: Background Initialization corrected medium error (VD 00/0 at 5349cb, PD 00(e0x20/s0) at 5349cb): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:25 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 16.26%(225s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:25 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 16.54%(241s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:24 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 14.41%(192s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:24 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 15.97%(208s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:24 2013
Category : Storage Service
Description : Controller event log: Unexpected sense: PD 00(e0x20/s0) Path 5000c5002135f7a9, CDB: 28 00 00 53 49 80 00 00 80 00, Sense: 3/11/00: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:24 2013
Category : Storage Service
Description : Controller event log: Unexpected sense: PD 00(e0x20/s0) Path 5000c5002135f7a9, CDB: 28 00 00 53 49 c9 00 00 37 00, Sense: 3/11/00: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:24 2013
Category : Storage Service
Description : Controller event log: Unexpected sense: PD 00(e0x20/s0) Path 5000c5002135f7a9, CDB: 28 00 00 53 49 ca 00 00 36 00, Sense: 3/11/00: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:24 2013
Category : Storage Service
Description : Controller event log: Unexpected sense: PD 00(e0x20/s0) Path 5000c5002135f7a9, CDB: 28 00 00 53 49 cb 00 00 35 00, Sense: 3/11/00: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:24 2013
Category : Storage Service
Description : Controller event log: Background Initialization corrected medium error (VD 00/0 at 5349c8, PD 00(e0x20/s0) at 5349c8): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:24 2013
Category : Storage Service
Description : Controller event log: Background Initialization corrected medium error (VD 00/0 at 5349c9, PD 00(e0x20/s0) at 5349c9): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:23 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 9.37%(144s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:23 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 11.19%(160s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:23 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 12.76%(176s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:22 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 3.67%(80s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:22 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 4.59%(96s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:22 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 6.27%(112s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:22 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 7.83%(128s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 1013
Date and Time : Mon Oct 14 18:39:22 2013
Category : Instrumentation Service
Description : System Peak Power detected new peak value
Peak value (in Watts): 311

Severity : Non-Critical
ID : 2335
Date and Time : Mon Oct 14 18:39:21 2013
Category : Storage Service
Description : Controller event log: BBU disabled; changing WB virtual disks to WT: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:21 2013
Category : Storage Service
Description : Controller event log: Policy change on VD 00/0 to [ID=00,dcp=0d,ccp=0c,ap=0,dc=0,dbgi=0,S=0|0] from [ID=00,dcp=0d,ccp=0d,ap=0,dc=0,dbgi=0,S=0|0]: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:21 2013
Category : Storage Service
Description : Controller event log: Policy change on VD 01/1 to [ID=01,dcp=0d,ccp=0c,ap=0,dc=0,dbgi=0,S=0|0] from [ID=01,dcp=0d,ccp=0d,ap=0,dc=0,dbgi=0,S=0|0]: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:21 2013
Category : Storage Service
Description : Controller event log: Background Initialization started on VD 00/0: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:21 2013
Category : Storage Service
Description : Controller event log: Background Initialization started on VD 01/1: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:21 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 0.33%(16s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:21 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 0.92%(32s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:21 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 2.61%(48s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:21 2013
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 3.41%(64s): Controller 0 (PERC H700 Integrated)

Severity : Non-Critical
ID : 2335
Date and Time : Mon Oct 14 18:39:20 2013
Category : Storage Service
Description : Controller event log: Current capacity of the battery is below threshold: Controller 0 (PERC H700 Integrated)

Severity : Non-Critical
ID : 2335
Date and Time : Mon Oct 14 18:39:19 2013
Category : Storage Service
Description : Controller event log: Battery needs replacement - SOH Bad: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:18 2013
Category : Storage Service
Description : Controller event log: Time established as 10/14/13 16:14:28; (40 seconds since power on): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:18 2013
Category : Storage Service
Description : Controller event log: Battery temperature is normal: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:17 2013
Category : Storage Service
Description : Controller event log: Inserted: PD 02(e0x20/s2): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:17 2013
Category : Storage Service
Description : Controller event log: Inserted: PD 03(e0x20/s3): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:17 2013
Category : Storage Service
Description : Controller event log: Inserted: PD 04(e0x20/s4): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:17 2013
Category : Storage Service
Description : Controller event log: Inserted: PD 05(e0x20/s5): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:16 2013
Category : Storage Service
Description : Controller event log: Board Revision A03: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:16 2013
Category : Storage Service
Description : Controller event log: Enclosure PD 20(c None/p0) communication restored: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:16 2013
Category : Storage Service
Description : Controller event log: Inserted: Encl PD 20: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:16 2013
Category : Storage Service
Description : Controller event log: Inserted: PD 00(e0x20/s0): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:16 2013
Category : Storage Service
Description : Controller event log: Inserted: PD 01(e0x20/s1): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:15 2013
Category : Storage Service
Description : Controller event log: Firmware initialization started (PCI ID 0079/1000/1f17/1028): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:15 2013
Category : Storage Service
Description : Controller event log: Battery Present: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:15 2013
Category : Storage Service
Description : Controller event log: Package version 12.3.0-0032: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:14 2013
Category : Storage Service
Description : Controller event log: Firmware initialization started (PCI ID 0079/1000/1f17/1028): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:14 2013
Category : Storage Service
Description : Controller event log: Battery Present: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:14 2013
Category : Storage Service
Description : Controller event log: Package version 12.3.0-0032: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:14 2013
Category : Storage Service
Description : Controller event log: Board Revision A03: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:13 2013
Category : Storage Service
Description : Controller event log: Policy change on VD 01/1 to [ID=01,dcp=0d,ccp=0c,ap=0,dc=0,dbgi=0,S=0|1] from [ID=01,dcp=0d,ccp=0d,ap=0,dc=0,dbgi=0,S=0|1]: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:13 2013
Category : Storage Service
Description : Controller event log: Fast initialization started on VD 01/1: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:13 2013
Category : Storage Service
Description : Controller event log: Initialization complete on VD 01/1: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:13 2013
Category : Storage Service
Description : Controller event log: VD bad block table on VD 01/1 is cleared: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:12 2013
Category : Storage Service
Description : Controller event log: Created VD 01/1: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:12 2013
Category : Storage Service
Description : Controller event log: VD 01/1 is available: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:12 2013
Category : Storage Service
Description : Controller event log: Policy change on VD 00/0 to [ID=00,dcp=0d,ccp=0d,ap=0,dc=0,dbgi=0,S=0|1] from [ID=00,dcp=0d,ccp=0c,ap=0,dc=0,dbgi=0,S=0|1]: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:12 2013
Category : Storage Service
Description : Controller event log: Policy change on VD 00/0 to [ID=00,dcp=0d,ccp=0c,ap=0,dc=0,dbgi=0,S=0|1] from [ID=00,dcp=0d,ccp=0d,ap=0,dc=0,dbgi=0,S=0|1]: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:11 2013
Category : Storage Service
Description : Controller event log: Fast initialization started on VD 00/0: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:11 2013
Category : Storage Service
Description : Controller event log: Initialization complete on VD 00/0: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:11 2013
Category : Storage Service
Description : Controller event log: VD bad block table on VD 00/0 is cleared: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:11 2013
Category : Storage Service
Description : Controller event log: VD 01/1 is now OPTIMAL: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:10 2013
Category : Storage Service
Description : Controller event log: VD 00/0 is now OPTIMAL: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:10 2013
Category : Storage Service
Description : Controller event log: Created VD 00/0: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:10 2013
Category : Storage Service
Description : Controller event log: VD 00/0 is available: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:10 2013
Category : Storage Service
Description : Controller event log: Policy change on VD 00/0 to [ID=00,dcp=0d,ccp=0c,ap=0,dc=0,dbgi=0,S=0|1] from [ID=00,dcp=0d,ccp=0d,ap=0,dc=0,dbgi=0,S=0|1]: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:09 2013
Category : Storage Service
Description : Controller event log: State change on PD 02(e0x20/s2) from UNCONFIGURED_GOOD(0) to ONLINE(18): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:09 2013
Category : Storage Service
Description : Controller event log: State change on PD 03(e0x20/s3) from UNCONFIGURED_GOOD(0) to ONLINE(18): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:09 2013
Category : Storage Service
Description : Controller event log: State change on PD 04(e0x20/s4) from UNCONFIGURED_GOOD(0) to ONLINE(18): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:09 2013
Category : Storage Service
Description : Controller event log: State change on PD 05(e0x20/s5) from UNCONFIGURED_GOOD(0) to ONLINE(18): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:08 2013
Category : Storage Service
Description : Controller event log: State change on PD 02(e0x20/s2) from ONLINE(18) to UNCONFIGURED_GOOD(0): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:08 2013
Category : Storage Service
Description : Controller event log: State change on PD 05(e0x20/s5) from ONLINE(18) to UNCONFIGURED_GOOD(0): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:08 2013
Category : Storage Service
Description : Controller event log: State change on PD 00(e0x20/s0) from UNCONFIGURED_GOOD(0) to ONLINE(18): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:08 2013
Category : Storage Service
Description : Controller event log: State change on PD 01(e0x20/s1) from UNCONFIGURED_GOOD(0) to ONLINE(18): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:07 2013
Category : Storage Service
Description : Controller event log: Deleted VD 00/0: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:07 2013
Category : Storage Service
Description : Controller event log: Deleted VD 01/0: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:07 2013
Category : Storage Service
Description : Controller event log: State change on PD 00(e0x20/s0) from ONLINE(18) to UNCONFIGURED_GOOD(0): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:07 2013
Category : Storage Service
Description : Controller event log: State change on PD 01(e0x20/s1) from ONLINE(18) to UNCONFIGURED_GOOD(0): Controller 0 (PERC H700 Integrated)

Severity : Non-Critical
ID : 2335
Date and Time : Mon Oct 14 18:39:06 2013
Category : Storage Service
Description : Controller event log: BBU disabled; changing WB virtual disks to WT: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:06 2013
Category : Storage Service
Description : Controller event log: Policy change on VD 00/0 to [ID=00,dcp=0d,ccp=0c,ap=0,dc=0,dbgi=0,S=0|0] from [ID=00,dcp=0d,ccp=0d,ap=0,dc=0,dbgi=0,S=0|0]: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:06 2013
Category : Storage Service
Description : Controller event log: Policy change on VD 01/1 to [ID=01,dcp=0d,ccp=0c,ap=0,dc=0,dbgi=0,S=0|0] from [ID=01,dcp=0d,ccp=0d,ap=0,dc=0,dbgi=0,S=0|0]: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:06 2013
Category : Storage Service
Description : Controller event log: Time established as 10/14/13 16:11:35; (70 seconds since power on): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:05 2013
Category : Storage Service
Description : Controller event log: Battery temperature is normal: Controller 0 (PERC H700 Integrated)

Severity : Non-Critical
ID : 2335
Date and Time : Mon Oct 14 18:39:05 2013
Category : Storage Service
Description : Controller event log: Battery needs replacement - SOH Bad: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:05 2013
Category : Storage Service
Description : Controller event log: Battery started charging: Controller 0 (PERC H700 Integrated)

Severity : Non-Critical
ID : 2335
Date and Time : Mon Oct 14 18:39:05 2013
Category : Storage Service
Description : Controller event log: Current capacity of the battery is below threshold: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:04 2013
Category : Storage Service
Description : Controller event log: Inserted: PD 02(e0x20/s2): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:04 2013
Category : Storage Service
Description : Controller event log: Inserted: PD 03(e0x20/s3): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:04 2013
Category : Storage Service
Description : Controller event log: Inserted: PD 04(e0x20/s4): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:04 2013
Category : Storage Service
Description : Controller event log: Inserted: PD 05(e0x20/s5): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:03 2013
Category : Storage Service
Description : Controller event log: Enclosure PD 20(c None/p0) communication restored: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:03 2013
Category : Storage Service
Description : Controller event log: Inserted: Encl PD 20: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:03 2013
Category : Storage Service
Description : Controller event log: Inserted: PD 00(e0x20/s0): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:03 2013
Category : Storage Service
Description : Controller event log: Inserted: PD 01(e0x20/s1): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:02 2013
Category : Storage Service
Description : Controller event log: Firmware initialization started (PCI ID 0079/1000/1f17/1028): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:02 2013
Category : Storage Service
Description : Controller event log: Battery Present: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:02 2013
Category : Storage Service
Description : Controller event log: Package version 12.3.0-0032: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:02 2013
Category : Storage Service
Description : Controller event log: Board Revision A03: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:01 2013
Category : Storage Service
Description : Controller event log: Firmware initialization started (PCI ID 0079/1000/1f17/1028): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:01 2013
Category : Storage Service
Description : Controller event log: Battery Present: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:01 2013
Category : Storage Service
Description : Controller event log: Package version 12.3.0-0032: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:01 2013
Category : Storage Service
Description : Controller event log: Board Revision A03: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:00 2013
Category : Storage Service
Description : Controller event log: Firmware initialization started (PCI ID 0079/1000/1f17/1028): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:00 2013
Category : Storage Service
Description : Controller event log: Battery Present: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:00 2013
Category : Storage Service
Description : Controller event log: Package version 12.3.0-0032: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:39:00 2013
Category : Storage Service
Description : Controller event log: Board Revision A03: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:59 2013
Category : Storage Service
Description : Controller event log: State change on PD 03(e0x20/s3) from FAILED(11) to UNCONFIGURED_BAD(1): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:59 2013
Category : Storage Service
Description : Controller event log: Inserted: PD 03(e0x20/s3): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:59 2013
Category : Storage Service
Description : Controller event log: State change on PD 03(e0x20/s3) from UNCONFIGURED_BAD(1) to UNCONFIGURED_GOOD(0): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:59 2013
Category : Storage Service
Description : Controller event log: Battery charge complete: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:58 2013
Category : Storage Service
Description : Controller event log: Policy change on VD 00/0 to [ID=00,dcp=0d,ccp=0c,ap=0,dc=0,dbgi=0,S=0|0] from [ID=00,dcp=0d,ccp=0d,ap=0,dc=0,dbgi=0,S=0|0]: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:58 2013
Category : Storage Service
Description : Controller event log: Policy change on VD 01/1 to [ID=01,dcp=0d,ccp=0c,ap=0,dc=0,dbgi=0,S=0|0] from [ID=01,dcp=0d,ccp=0d,ap=0,dc=0,dbgi=0,S=0|0]: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:58 2013
Category : Storage Service
Description : Controller event log: Inserted: PD 04(e0x20/s4): Controller 0 (PERC H700 Integrated)

Severity : Non-Critical
ID : 2335
Date and Time : Mon Oct 14 18:38:58 2013
Category : Storage Service
Description : Controller event log: Removed: PD 03(e0x20/s3): Controller 0 (PERC H700 Integrated)

Severity : Non-Critical
ID : 2335
Date and Time : Mon Oct 14 18:38:57 2013
Category : Storage Service
Description : Controller event log: Battery needs replacement - SOH Bad: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:57 2013
Category : Storage Service
Description : Controller event log: Battery started charging: Controller 0 (PERC H700 Integrated)

Severity : Non-Critical
ID : 2335
Date and Time : Mon Oct 14 18:38:57 2013
Category : Storage Service
Description : Controller event log: Current capacity of the battery is below threshold: Controller 0 (PERC H700 Integrated)

Severity : Non-Critical
ID : 2335
Date and Time : Mon Oct 14 18:38:57 2013
Category : Storage Service
Description : Controller event log: BBU disabled; changing WB virtual disks to WT: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:56 2013
Category : Storage Service
Description : Controller event log: Inserted: PD 03(e0x20/s3): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:56 2013
Category : Storage Service
Description : Controller event log: Inserted: PD 05(e0x20/s5): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:56 2013
Category : Storage Service
Description : Controller event log: Time established as 10/14/13 11:06:59; (38 seconds since power on): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:56 2013
Category : Storage Service
Description : Controller event log: Battery temperature is normal: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:55 2013
Category : Storage Service
Description : Controller event log: Inserted: Encl PD 20: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:55 2013
Category : Storage Service
Description : Controller event log: Inserted: PD 00(e0x20/s0): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:55 2013
Category : Storage Service
Description : Controller event log: Inserted: PD 01(e0x20/s1): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:55 2013
Category : Storage Service
Description : Controller event log: Inserted: PD 02(e0x20/s2): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:54 2013
Category : Storage Service
Description : Controller event log: Battery Present: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:54 2013
Category : Storage Service
Description : Controller event log: Package version 12.3.0-0032: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:54 2013
Category : Storage Service
Description : Controller event log: Board Revision A03: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:54 2013
Category : Storage Service
Description : Controller event log: Enclosure PD 20(c None/p0) communication restored: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:53 2013
Category : Storage Service
Description : Controller event log: Battery Present: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:53 2013
Category : Storage Service
Description : Controller event log: Package version 12.3.0-0032: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:53 2013
Category : Storage Service
Description : Controller event log: Board Revision A03: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:53 2013
Category : Storage Service
Description : Controller event log: Firmware initialization started (PCI ID 0079/1000/1f17/1028): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:52 2013
Category : Storage Service
Description : Controller event log: State change on VD 01/1 from DEGRADED(2) to OFFLINE(0): Controller 0 (PERC H700 Integrated)

Severity : Non-Critical
ID : 2335
Date and Time : Mon Oct 14 18:38:52 2013
Category : Storage Service
Description : Controller event log: VD 01/1 is now OFFLINE: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:52 2013
Category : Storage Service
Description : Controller event log: State change on PD 04(e0x20/s4) from FAILED(11) to UNCONFIGURED_BAD(1): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:52 2013
Category : Storage Service
Description : Controller event log: Firmware initialization started (PCI ID 0079/1000/1f17/1028): Controller 0 (PERC H700 Integrated)

Severity : Non-Critical
ID : 2335
Date and Time : Mon Oct 14 18:38:51 2013
Category : Storage Service
Description : Controller event log: Removed: PD 04(e0x20/s4): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:51 2013
Category : Storage Service
Description : Controller event log: State change on PD 04(e0x20/s4) from ONLINE(18) to FAILED(11): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:51 2013
Category : Storage Service
Description : Controller event log: State change on VD 00/0 from DEGRADED(2) to OFFLINE(0): Controller 0 (PERC H700 Integrated)

Severity : Non-Critical
ID : 2335
Date and Time : Mon Oct 14 18:38:51 2013
Category : Storage Service
Description : Controller event log: VD 00/0 is now OFFLINE: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:50 2013
Category : Storage Service
Description : Controller event log: Patrol Read progress on PD 00(e0x20/s0) is 99.99%(54429s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:50 2013
Category : Storage Service
Description : Controller event log: Patrol Read progress on PD 05(e0x20/s5) is 99.99%(57133s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:50 2013
Category : Storage Service
Description : Controller event log: Patrol Read complete: Controller 0 (PERC H700 Integrated)

Severity : Non-Critical
ID : 2335
Date and Time : Mon Oct 14 18:38:50 2013
Category : Storage Service
Description : Controller event log: PD 04(e0x20/s4) Path 5000c50021360ac9 reset (Type 03): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:49 2013
Category : Storage Service
Description : Controller event log: Patrol Read progress on PD 05(e0x20/s5) is 89.99%(32488s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:49 2013
Category : Storage Service
Description : Controller event log: Battery charge complete: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:49 2013
Category : Storage Service
Description : Controller event log: Patrol Read progress on PD 01(e0x20/s1) is 99.99%(42306s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:49 2013
Category : Storage Service
Description : Controller event log: Patrol Read progress on PD 02(e0x20/s2) is 99.99%(47540s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:49 2013
Category : Storage Service
Description : Controller event log: Patrol Read progress on PD 04(e0x20/s4) is 99.99%(47740s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:48 2013
Category : Storage Service
Description : Controller event log: Patrol Read progress on PD 04(e0x20/s4) is 89.99%(23661s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:48 2013
Category : Storage Service
Description : Controller event log: Patrol Read progress on PD 02(e0x20/s2) is 89.99%(24059s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:48 2013
Category : Storage Service
Description : Controller event log: Patrol Read progress on PD 00(e0x20/s0) is 89.99%(30557s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:47 2013
Category : Storage Service
Description : Controller event log: Patrol Read progress on PD 01(e0x20/s1) is 89.99%(18990s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:47 2013
Category : Storage Service
Description : Controller event log: Battery relearn completed: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:47 2013
Category : Storage Service
Description : Controller event log: Battery started charging: Controller 0 (PERC H700 Integrated)

Severity : Non-Critical
ID : 2335
Date and Time : Mon Oct 14 18:38:47 2013
Category : Storage Service
Description : Controller event log: Current capacity of the battery is below threshold: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:46 2013
Category : Storage Service
Description : Controller event log: Battery relearn pending: Battery is under charge: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:46 2013
Category : Storage Service
Description : Controller event log: Battery relearn started: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:46 2013
Category : Storage Service
Description : Controller event log: Battery is discharging: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:46 2013
Category : Storage Service
Description : Controller event log: Battery relearn in progress: Controller 0 (PERC H700 Integrated)

Severity : Non-Critical
ID : 2335
Date and Time : Mon Oct 14 18:38:45 2013
Category : Storage Service
Description : Controller event log: Puncturing bad block on PD 00(e0x20/s0) at 5bafcc: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:45 2013
Category : Storage Service
Description : Controller event log: Patrol Read progress on PD 04(e0x20/s4) is 79.99%(4515s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:45 2013
Category : Storage Service
Description : Controller event log: Patrol Read progress on PD 02(e0x20/s2) is 79.99%(4895s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:45 2013
Category : Storage Service
Description : Controller event log: Patrol Read progress on PD 00(e0x20/s0) is 79.99%(10908s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:45 2013
Category : Storage Service
Description : Controller event log: Patrol Read progress on PD 05(e0x20/s5) is 79.99%(11375s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:44 2013
Category : Storage Service
Description : Controller event log: Unexpected sense: PD 00(e0x20/s0) Path 5000c5002135f7a9, CDB: 28 00 00 5b af ca 00 00 08 00, Sense: 3/11/00: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:44 2013
Category : Storage Service
Description : Controller event log: Unexpected sense: PD 00(e0x20/s0) Path 5000c5002135f7a9, CDB: 28 00 00 5b af c2 00 00 10 00, Sense: 3/11/00: Controller 0 (PERC H700 Integrated)

Severity : Non-Critical
ID : 2335
Date and Time : Mon Oct 14 18:38:44 2013
Category : Storage Service
Description : Controller event log: Unrecoverable medium error during recovery on PD 00(e0x20/s0) at 5bafcc: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:43 2013
Category : Storage Service
Description : Controller event log: Patrol Read progress on PD 05(e0x20/s5) is 69.99%(59160s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:43 2013
Category : Storage Service
Description : Controller event log: Patrol Read progress on PD 00(e0x20/s0) is 69.99%(59251s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:43 2013
Category : Storage Service
Description : Controller event log: Battery relearn will start in 5 hours: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:43 2013
Category : Storage Service
Description : Controller event log: Patrol Read progress on PD 01(e0x20/s1) is 79.99%(962s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:42 2013
Category : Storage Service
Description : Controller event log: Patrol Read progress on PD 01(e0x20/s1) is 69.99%(50942s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:42 2013
Category : Storage Service
Description : Controller event log: Patrol Read progress on PD 04(e0x20/s4) is 69.99%(53493s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:42 2013
Category : Storage Service
Description : Controller event log: Patrol Read progress on PD 02(e0x20/s2) is 69.99%(54454s): Controller 0 (PERC H700 Integrated)

Severity : Non-Critical
ID : 2335
Date and Time : Mon Oct 14 18:38:42 2013
Category : Storage Service
Description : Controller event log: Predictive failure: PD 04(e0x20/s4): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:41 2013
Category : Storage Service
Description : Controller event log: Patrol Read progress on PD 04(e0x20/s4) is 59.99%(37075s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:41 2013
Category : Storage Service
Description : Controller event log: Patrol Read progress on PD 02(e0x20/s2) is 59.99%(38130s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:41 2013
Category : Storage Service
Description : Controller event log: Patrol Read progress on PD 00(e0x20/s0) is 59.99%(42221s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:41 2013
Category : Storage Service
Description : Controller event log: Patrol Read progress on PD 05(e0x20/s5) is 59.99%(42543s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:40 2013
Category : Storage Service
Description : Controller event log: Patrol Read progress on PD 05(e0x20/s5) is 39.99%(1306s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:40 2013
Category : Storage Service
Description : Controller event log: Patrol Read progress on PD 01(e0x20/s1) is 49.99%(14383s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:40 2013
Category : Storage Service
Description : Controller event log: Patrol Read progress on PD 04(e0x20/s4) is 49.99%(16170s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:40 2013
Category : Storage Service
Description : Controller event log: Patrol Read progress on PD 02(e0x20/s2) is 49.99%(16375s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:40 2013
Category : Storage Service
Description : Controller event log: Patrol Read progress on PD 00(e0x20/s0) is 49.99%(21427s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:40 2013
Category : Storage Service
Description : Controller event log: Patrol Read progress on PD 05(e0x20/s5) is 49.99%(22854s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:40 2013
Category : Storage Service
Description : Controller event log: Patrol Read progress on PD 01(e0x20/s1) is 59.99%(34392s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:39 2013
Category : Storage Service
Description : Controller event log: Patrol Read progress on PD 02(e0x20/s2) is 39.99%(62122s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:39 2013
Category : Storage Service
Description : Controller event log: Patrol Read progress on PD 04(e0x20/s4) is 39.99%(62313s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:39 2013
Category : Storage Service
Description : Controller event log: Patrol Read progress on PD 00(e0x20/s0) is 39.99%(468s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:38 2013
Category : Storage Service
Description : Controller event log: Patrol Read progress on PD 00(e0x20/s0) is 19.99%(34529s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:38 2013
Category : Storage Service
Description : Controller event log: Patrol Read progress on PD 05(e0x20/s5) is 19.99%(35462s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:38 2013
Category : Storage Service
Description : Controller event log: Patrol Read progress on PD 01(e0x20/s1) is 29.99%(46069s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:38 2013
Category : Storage Service
Description : Controller event log: Patrol Read progress on PD 02(e0x20/s2) is 29.99%(47536s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:38 2013
Category : Storage Service
Description : Controller event log: Patrol Read progress on PD 04(e0x20/s4) is 29.99%(47592s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:38 2013
Category : Storage Service
Description : Controller event log: Patrol Read progress on PD 00(e0x20/s0) is 29.99%(49201s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:38 2013
Category : Storage Service
Description : Controller event log: Patrol Read progress on PD 05(e0x20/s5) is 29.99%(50580s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:38 2013
Category : Storage Service
Description : Controller event log: Battery relearn will start in 1 day: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:38 2013
Category : Storage Service
Description : Controller event log: Patrol Read progress on PD 01(e0x20/s1) is 39.99%(60201s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:37 2013
Category : Storage Service
Description : Controller event log: Patrol Read progress on PD 00(e0x20/s0) is 9.99%(20324s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:37 2013
Category : Storage Service
Description : Controller event log: Patrol Read progress on PD 05(e0x20/s5) is 9.99%(20631s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:37 2013
Category : Storage Service
Description : Controller event log: Patrol Read progress on PD 01(e0x20/s1) is 19.99%(32368s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:37 2013
Category : Storage Service
Description : Controller event log: Patrol Read progress on PD 04(e0x20/s4) is 19.99%(33503s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:37 2013
Category : Storage Service
Description : Controller event log: Patrol Read progress on PD 02(e0x20/s2) is 19.99%(33580s): Controller 0 (PERC H700 Integrated)

Severity : Non-Critical
ID : 2335
Date and Time : Mon Oct 14 18:38:37 2013
Category : Storage Service
Description : Controller event log: Predictive failure: PD 04(e0x20/s4): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:36 2013
Category : Storage Service
Description : Controller event log: Unexpected sense: PD 00(e0x20/s0) Path 5000c5002135f7a9, CDB: 2f 00 00 53 49 ca 00 10 00 00, Sense: 3/11/00: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:36 2013
Category : Storage Service
Description : Controller event log: Unexpected sense: PD 00(e0x20/s0) Path 5000c5002135f7a9, CDB: 2f 00 00 53 49 cb 00 10 00 00, Sense: 3/11/00: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:36 2013
Category : Storage Service
Description : Controller event log: Unexpected sense: PD 00(e0x20/s0) Path 5000c5002135f7a9, CDB: 2f 00 00 5b a9 cc 00 10 00 00, Sense: 3/11/00: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:36 2013
Category : Storage Service
Description : Controller event log: Patrol Read progress on PD 01(e0x20/s1) is 9.99%(19430s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:36 2013
Category : Storage Service
Description : Controller event log: Patrol Read progress on PD 02(e0x20/s2) is 9.99%(20075s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:36 2013
Category : Storage Service
Description : Controller event log: Patrol Read progress on PD 04(e0x20/s4) is 9.99%(20163s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:35 2013
Category : Storage Service
Description : Controller event log: Patrol Read started: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:35 2013
Category : Storage Service
Description : Controller event log: Patrol Read progress on PD 02(e0x20/s2) is 0.00%(0s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:35 2013
Category : Storage Service
Description : Controller event log: Patrol Read progress on PD 01(e0x20/s1) is 0.00%(0s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:35 2013
Category : Storage Service
Description : Controller event log: Patrol Read progress on PD 00(e0x20/s0) is 0.00%(0s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:35 2013
Category : Storage Service
Description : Controller event log: Patrol Read progress on PD 05(e0x20/s5) is 0.00%(0s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:35 2013
Category : Storage Service
Description : Controller event log: Patrol Read progress on PD 04(e0x20/s4) is 0.00%(0s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:35 2013
Category : Storage Service
Description : Controller event log: Unexpected sense: PD 00(e0x20/s0) Path 5000c5002135f7a9, CDB: 2f 00 00 53 40 00 00 10 00 00, Sense: 3/11/00: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:35 2013
Category : Storage Service
Description : Controller event log: Unexpected sense: PD 00(e0x20/s0) Path 5000c5002135f7a9, CDB: 2f 00 00 53 49 c9 00 10 00 00, Sense: 3/11/00: Controller 0 (PERC H700 Integrated)

Severity : Non-Critical
ID : 2335
Date and Time : Mon Oct 14 18:38:34 2013
Category : Storage Service
Description : Controller event log: Unrecoverable medium error during recovery on PD 00(e0x20/s0) at 5bafcc: Controller 0 (PERC H700 Integrated)

Severity : Non-Critical
ID : 2335
Date and Time : Mon Oct 14 18:38:34 2013
Category : Storage Service
Description : Controller event log: Puncturing bad block on PD 00(e0x20/s0) at 5bafcc: Controller 0 (PERC H700 Integrated)

Severity : Non-Critical
ID : 2335
Date and Time : Mon Oct 14 18:38:34 2013
Category : Storage Service
Description : Controller event log: Predictive failure: PD 04(e0x20/s4): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:34 2013
Category : Storage Service
Description : Controller event log: Battery relearn will start in 2 day: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:30 2013
Category : Storage Service
Description : Controller event log: Unexpected sense: PD 00(e0x20/s0) Path 5000c5002135f7a9, CDB: 28 00 00 5b af c2 00 00 10 00, Sense: 3/11/00: Controller 0 (PERC H700 Integrated)

Severity : Non-Critical
ID : 2335
Date and Time : Mon Oct 14 18:38:29 2013
Category : Storage Service
Description : Controller event log: Predictive failure: PD 04(e0x20/s4): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:29 2013
Category : Storage Service
Description : Controller event log: Battery relearn will start in 4 days: Controller 0 (PERC H700 Integrated)

Severity : Non-Critical
ID : 2335
Date and Time : Mon Oct 14 18:38:29 2013
Category : Storage Service
Description : Controller event log: Predictive failure: PD 04(e0x20/s4): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:29 2013
Category : Storage Service
Description : Controller event log: Unexpected sense: PD 00(e0x20/s0) Path 5000c5002135f7a9, CDB: 28 00 00 5b af c2 00 00 10 00, Sense: 3/11/00: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:28 2013
Category : Storage Service
Description : Controller event log: Unexpected sense: Encl PD 20 Path 5942b0b05992f600, CDB: 1c 01 80 04 00 00, Sense: 5/24/00: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Mon Oct 14 18:38:28 2013
Category : Storage Service
Description : Controller event log: Unexpected sense: Encl PD 20 Path 5942b0b05992f600, CDB: 1c 01 80 04 00 00, Sense: 5/24/00: Controller 0 (PERC H700 Integrated)

Severity : Critical
ID : 2048
Date and Time : Mon Oct 14 18:38:23 2013
Category : Storage Service
Description : Device failed: Battery 0 Controller 0

Severity : Critical
ID : 2169
Date and Time : Mon Oct 14 18:38:22 2013
Category : Storage Service
Description : The controller battery needs to be replaced.: Battery 0 Controller 0

Severity : Ok
ID : 1000
Date and Time : Mon Oct 14 18:38:16 2013
Category : Instrumentation Service
Description : Server Administrator starting

Severity : Ok
ID : 1012
Date and Time : Mon Oct 14 18:38:16 2013
Category : Instrumentation Service
Description : IPMI status
Interface: User

Severity : Ok
ID : 1001
Date and Time : Mon Oct 14 18:38:16 2013
Category : Instrumentation Service
Description : Server Administrator startup complete

Severity : Ok
ID : 1008
Date and Time : Mon Oct 14 18:38:16 2013
Category : Instrumentation Service
Description : Systems Management Data Manager Started

Severity : Ok
ID : 2334
Date and Time : Wed Mar 09 11:43:31 2011
Category : Storage Service
Description : Controller event log: Current capacity of the battery is above threshold: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Mar 09 11:43:31 2011
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 97.25%(4581s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Mar 09 11:43:31 2011
Category : Storage Service
Description : Controller event log: Battery charge complete: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Mar 09 11:43:28 2011
Category : Storage Service
Description : Controller event log: Time established as 03/09/11 11:40:31; (38 seconds since power on): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Mar 09 11:43:28 2011
Category : Storage Service
Description : Controller event log: Battery temperature is normal: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Mar 09 11:43:28 2011
Category : Storage Service
Description : Controller event log: Battery started charging: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Mar 09 11:43:27 2011
Category : Storage Service
Description : Controller event log: Background Initialization started on VD 00/0: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Mar 09 11:43:27 2011
Category : Storage Service
Description : Controller event log: Background Initialization started on VD 01/1: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Mar 09 11:43:27 2011
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 97.18%(4523s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Mar 09 11:43:27 2011
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 01/1 is 14.78%(4522s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Mar 09 11:43:26 2011
Category : Storage Service
Description : Controller event log: Enclosure PD 20(c None/p0) communication restored: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Mar 09 11:43:26 2011
Category : Storage Service
Description : Controller event log: Inserted: Encl PD 20: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Mar 09 11:43:26 2011
Category : Storage Service
Description : Controller event log: Inserted: PD 00(e0x20/s0): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Mar 09 11:43:26 2011
Category : Storage Service
Description : Controller event log: Inserted: PD 01(e0x20/s1): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Mar 09 11:43:25 2011
Category : Storage Service
Description : Controller event log: Firmware initialization started (PCI ID 0079/1000/1f17/1028): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Mar 09 11:43:25 2011
Category : Storage Service
Description : Controller event log: Battery Present: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Mar 09 11:43:25 2011
Category : Storage Service
Description : Controller event log: Package version 12.3.0-0032: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Mar 09 11:43:25 2011
Category : Storage Service
Description : Controller event log: Board Revision A03: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Mar 09 11:43:24 2011
Category : Storage Service
Description : Controller event log: Shutdown command received from host: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Mar 09 11:43:24 2011
Category : Storage Service
Description : Controller event log: Firmware initialization started (PCI ID 0079/1000/1f17/1028): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Mar 09 11:43:24 2011
Category : Storage Service
Description : Controller event log: Battery Present: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Mar 09 11:43:24 2011
Category : Storage Service
Description : Controller event log: Package version 12.3.0-0032: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Mar 09 11:43:24 2011
Category : Storage Service
Description : Controller event log: Board Revision A03: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 1000
Date and Time : Wed Mar 09 11:43:18 2011
Category : Instrumentation Service
Description : Server Administrator starting

Severity : Critical
ID : 1354
Date and Time : Wed Mar 09 11:43:18 2011
Category : Instrumentation Service
Description : Power supply detected a failure
Sensor location: PS 2 Status
Chassis location: Main System Chassis
Previous state was: Unknown
Power Supply type: AC
Power Supply state: Presence detected, AC lost

Severity : Ok
ID : 1012
Date and Time : Wed Mar 09 11:43:18 2011
Category : Instrumentation Service
Description : IPMI status
Interface: User

Severity : Ok
ID : 1001
Date and Time : Wed Mar 09 11:43:18 2011
Category : Instrumentation Service
Description : Server Administrator startup complete

Severity : Ok
ID : 1008
Date and Time : Wed Mar 09 11:43:18 2011
Category : Instrumentation Service
Description : Systems Management Data Manager Started

Severity : Ok
ID : 2334
Date and Time : Wed Mar 09 10:49:34 2011
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 93.67%(1340s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Mar 09 10:49:34 2011
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 01/1 is 14.17%(1339s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Mar 09 10:49:34 2011
Category : Storage Service
Description : Controller event log: Time established as 03/09/11 10:46:31; (38 seconds since power on): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Mar 09 10:49:34 2011
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 01/1 is 14.17%(1355s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Mar 09 10:49:34 2011
Category : Storage Service
Description : Controller event log: Battery temperature is normal: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Mar 09 10:49:34 2011
Category : Storage Service
Description : Controller event log: Battery started charging: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Mar 09 10:49:34 2011
Category : Storage Service
Description : Controller event log: Current capacity of the battery is above threshold: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Mar 09 10:49:34 2011
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 93.76%(1422s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Mar 09 10:49:34 2011
Category : Storage Service
Description : Controller event log: Battery charge complete: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Mar 09 10:49:29 2011
Category : Storage Service
Description : Controller event log: Inserted: PD 00(e0x20/s0): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Mar 09 10:49:29 2011
Category : Storage Service
Description : Controller event log: Inserted: PD 01(e0x20/s1): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Mar 09 10:49:29 2011
Category : Storage Service
Description : Controller event log: Background Initialization started on VD 00/0: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Mar 09 10:49:29 2011
Category : Storage Service
Description : Controller event log: Background Initialization started on VD 01/1: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Mar 09 10:49:28 2011
Category : Storage Service
Description : Controller event log: Package version 12.3.0-0032: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Mar 09 10:49:28 2011
Category : Storage Service
Description : Controller event log: Board Revision A03: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Mar 09 10:49:28 2011
Category : Storage Service
Description : Controller event log: Enclosure PD 20(c None/p0) communication restored: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Mar 09 10:49:28 2011
Category : Storage Service
Description : Controller event log: Inserted: Encl PD 20: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Mar 09 10:49:27 2011
Category : Storage Service
Description : Controller event log: Package version 12.3.0-0032: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Mar 09 10:49:27 2011
Category : Storage Service
Description : Controller event log: Board Revision A03: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Mar 09 10:49:27 2011
Category : Storage Service
Description : Controller event log: Firmware initialization started (PCI ID 0079/1000/1f17/1028): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Mar 09 10:49:27 2011
Category : Storage Service
Description : Controller event log: Battery Present: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Mar 09 10:49:26 2011
Category : Storage Service
Description : Controller event log: Shutdown command received from host: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Mar 09 10:49:26 2011
Category : Storage Service
Description : Controller event log: Firmware initialization started (PCI ID 0079/1000/1f17/1028): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Mar 09 10:49:26 2011
Category : Storage Service
Description : Controller event log: Battery Present: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 1000
Date and Time : Wed Mar 09 10:49:21 2011
Category : Instrumentation Service
Description : Server Administrator starting

Severity : Critical
ID : 1354
Date and Time : Wed Mar 09 10:49:21 2011
Category : Instrumentation Service
Description : Power supply detected a failure
Sensor location: PS 2 Status
Chassis location: Main System Chassis
Previous state was: Unknown
Power Supply type: AC
Power Supply state: Presence detected, AC lost

Severity : Ok
ID : 1012
Date and Time : Wed Mar 09 10:49:21 2011
Category : Instrumentation Service
Description : IPMI status
Interface: User

Severity : Ok
ID : 1001
Date and Time : Wed Mar 09 10:49:21 2011
Category : Instrumentation Service
Description : Server Administrator startup complete

Severity : Ok
ID : 1008
Date and Time : Wed Mar 09 10:49:21 2011
Category : Instrumentation Service
Description : Systems Management Data Manager Started

Severity : Ok
ID : 2334
Date and Time : Wed Mar 09 10:39:44 2011
Category : Storage Service
Description : Controller event log: Current capacity of the battery is above threshold: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Mar 09 10:39:44 2011
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 93.27%(949s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Mar 09 10:39:43 2011
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 01/1 is 14.08%(849s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Mar 09 10:39:43 2011
Category : Storage Service
Description : Controller event log: Time established as 03/09/11 10:37:20; (37 seconds since power on): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Mar 09 10:39:43 2011
Category : Storage Service
Description : Controller event log: Battery temperature is normal: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Mar 09 10:39:43 2011
Category : Storage Service
Description : Controller event log: Battery started charging: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Mar 09 10:39:42 2011
Category : Storage Service
Description : Controller event log: Enclosure PD 20(c None/p0) communication restored: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Mar 09 10:39:42 2011
Category : Storage Service
Description : Controller event log: Inserted: Encl PD 20: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Mar 09 10:39:42 2011
Category : Storage Service
Description : Controller event log: Inserted: PD 00(e0x20/s0): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Mar 09 10:39:42 2011
Category : Storage Service
Description : Controller event log: Inserted: PD 01(e0x20/s1): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Mar 09 10:39:42 2011
Category : Storage Service
Description : Controller event log: Background Initialization started on VD 00/0: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Mar 09 10:39:42 2011
Category : Storage Service
Description : Controller event log: Background Initialization started on VD 01/1: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Mar 09 10:39:42 2011
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 93.16%(849s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Mar 09 10:39:41 2011
Category : Storage Service
Description : Controller event log: Board Revision A03: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Mar 09 10:39:40 2011
Category : Storage Service
Description : Controller event log: Board Revision A03: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Mar 09 10:39:40 2011
Category : Storage Service
Description : Controller event log: Firmware initialization started (PCI ID 0079/1000/1f17/1028): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Mar 09 10:39:40 2011
Category : Storage Service
Description : Controller event log: Battery Present: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Mar 09 10:39:40 2011
Category : Storage Service
Description : Controller event log: Package version 12.3.0-0032: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Mar 09 10:39:39 2011
Category : Storage Service
Description : Controller event log: Shutdown command received from host: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Mar 09 10:39:39 2011
Category : Storage Service
Description : Controller event log: Firmware initialization started (PCI ID 0079/1000/1f17/1028): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Mar 09 10:39:39 2011
Category : Storage Service
Description : Controller event log: Battery Present: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Wed Mar 09 10:39:39 2011
Category : Storage Service
Description : Controller event log: Package version 12.3.0-0032: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 1000
Date and Time : Wed Mar 09 10:39:33 2011
Category : Instrumentation Service
Description : Server Administrator starting

Severity : Critical
ID : 1354
Date and Time : Wed Mar 09 10:39:33 2011
Category : Instrumentation Service
Description : Power supply detected a failure
Sensor location: PS 2 Status
Chassis location: Main System Chassis
Previous state was: Unknown
Power Supply type: AC
Power Supply state: Presence detected, AC lost

Severity : Ok
ID : 1012
Date and Time : Wed Mar 09 10:39:33 2011
Category : Instrumentation Service
Description : IPMI status
Interface: User

Severity : Ok
ID : 1001
Date and Time : Wed Mar 09 10:39:33 2011
Category : Instrumentation Service
Description : Server Administrator startup complete

Severity : Ok
ID : 1008
Date and Time : Wed Mar 09 10:39:33 2011
Category : Instrumentation Service
Description : Systems Management Data Manager Started

Severity : Ok
ID : 2358
Date and Time : Wed Mar 09 02:27:58 2011
Category : Storage Service
Description : The battery charge cycle is complete.: Battery 0 Controller 0

Severity : Ok
ID : 2199
Date and Time : Tue Mar 08 23:19:29 2011
Category : Storage Service
Description : The virtual disk cache policy has changed.: Virtual Disk 1 (Virtual Disk 1) Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2279
Date and Time : Tue Mar 08 23:19:28 2011
Category : Storage Service
Description : The controller battery charge level is operating within normal limits: Battery 0 Controller 0

Severity : Ok
ID : 2189
Date and Time : Tue Mar 08 23:19:28 2011
Category : Storage Service
Description : The controller write policy has been changed to Write Back.: Battery 0 Controller 0

Severity : Ok
ID : 2199
Date and Time : Tue Mar 08 23:19:28 2011
Category : Storage Service
Description : The virtual disk cache policy has changed.: Virtual Disk 0 (vd1) Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2247
Date and Time : Tue Mar 08 22:05:48 2011
Category : Storage Service
Description : The controller battery is charging.: Battery 0 Controller 0

Severity : Ok
ID : 2278
Date and Time : Tue Mar 08 22:05:48 2011
Category : Storage Service
Description : The controller battery charge level is below a normal threshold.: Battery 0 Controller 0

Severity : Ok
ID : 2177
Date and Time : Tue Mar 08 22:05:33 2011
Category : Storage Service
Description : The controller battery Learn cycle has completed.: Battery 0 Controller 0

Severity : Ok
ID : 2199
Date and Time : Tue Mar 08 20:59:05 2011
Category : Storage Service
Description : The virtual disk cache policy has changed.: Virtual Disk 1 (Virtual Disk 1) Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2188
Date and Time : Tue Mar 08 20:59:04 2011
Category : Storage Service
Description : The controller write policy has been changed to Write Through.: Battery 0 Controller 0

Severity : Ok
ID : 2199
Date and Time : Tue Mar 08 20:59:04 2011
Category : Storage Service
Description : The virtual disk cache policy has changed.: Virtual Disk 0 (vd1) Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2278
Date and Time : Tue Mar 08 20:59:03 2011
Category : Storage Service
Description : The controller battery charge level is below a normal threshold.: Battery 0 Controller 0

Severity : Ok
ID : 2266
Date and Time : Tue Mar 08 19:55:33 2011
Category : Storage Service
Description : Controller log file entry: Battery 0 Controller 0

Severity : Ok
ID : 2248
Date and Time : Tue Mar 08 19:55:33 2011
Category : Storage Service
Description : The controller battery is executing a Learn cycle.: Battery 0 Controller 0

Severity : Ok
ID : 2358
Date and Time : Tue Mar 08 19:54:28 2011
Category : Storage Service
Description : The battery charge cycle is complete.: Battery 0 Controller 0

Severity : Ok
ID : 2176
Date and Time : Tue Mar 08 19:54:28 2011
Category : Storage Service
Description : The controller battery Learn cycle has started.: Battery 0 Controller 0

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 18:30:15 2011
Category : Storage Service
Description : Controller event log: Battery started charging: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 18:30:15 2011
Category : Storage Service
Description : Controller event log: Current capacity of the battery is above threshold: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 18:30:15 2011
Category : Storage Service
Description : Controller event log: Battery relearn pending: Battery is under charge: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 18:30:14 2011
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 01/1 is 1.62%(8238s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 18:30:14 2011
Category : Storage Service
Description : Controller event log: Time established as 03/08/11 18:27:15; (37 seconds since power on): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 18:30:14 2011
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 24.37%(8254s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 18:30:14 2011
Category : Storage Service
Description : Controller event log: Battery temperature is normal: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 18:30:13 2011
Category : Storage Service
Description : Controller event log: Inserted: PD 01(e0x20/s1): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 18:30:13 2011
Category : Storage Service
Description : Controller event log: Background Initialization started on VD 00/0: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 18:30:13 2011
Category : Storage Service
Description : Controller event log: Background Initialization started on VD 01/1: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 18:30:13 2011
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 24.35%(8238s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 18:30:12 2011
Category : Storage Service
Description : Controller event log: Board Revision A03: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 18:30:12 2011
Category : Storage Service
Description : Controller event log: Enclosure PD 20(c None/p0) communication restored: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 18:30:12 2011
Category : Storage Service
Description : Controller event log: Inserted: Encl PD 20: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 18:30:12 2011
Category : Storage Service
Description : Controller event log: Inserted: PD 00(e0x20/s0): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 18:30:11 2011
Category : Storage Service
Description : Controller event log: Board Revision A03: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 18:30:11 2011
Category : Storage Service
Description : Controller event log: Firmware initialization started (PCI ID 0079/1000/1f17/1028): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 18:30:11 2011
Category : Storage Service
Description : Controller event log: Battery Present: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 18:30:11 2011
Category : Storage Service
Description : Controller event log: Package version 12.3.0-0032: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 18:30:10 2011
Category : Storage Service
Description : Controller event log: Shutdown command received from host: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 18:30:10 2011
Category : Storage Service
Description : Controller event log: Firmware initialization started (PCI ID 0079/1000/1f17/1028): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 18:30:10 2011
Category : Storage Service
Description : Controller event log: Battery Present: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 18:30:10 2011
Category : Storage Service
Description : Controller event log: Package version 12.3.0-0032: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 1000
Date and Time : Tue Mar 08 18:30:05 2011
Category : Instrumentation Service
Description : Server Administrator starting

Severity : Critical
ID : 1354
Date and Time : Tue Mar 08 18:30:05 2011
Category : Instrumentation Service
Description : Power supply detected a failure
Sensor location: PS 2 Status
Chassis location: Main System Chassis
Previous state was: Unknown
Power Supply type: AC
Power Supply state: Presence detected, AC lost

Severity : Ok
ID : 1012
Date and Time : Tue Mar 08 18:30:05 2011
Category : Instrumentation Service
Description : IPMI status
Interface: User

Severity : Ok
ID : 1001
Date and Time : Tue Mar 08 18:30:05 2011
Category : Instrumentation Service
Description : Server Administrator startup complete

Severity : Ok
ID : 1008
Date and Time : Tue Mar 08 18:30:05 2011
Category : Instrumentation Service
Description : Systems Management Data Manager Started

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 18:11:55 2011
Category : Storage Service
Description : Controller event log: Battery started charging: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 18:11:55 2011
Category : Storage Service
Description : Controller event log: Current capacity of the battery is above threshold: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 18:11:55 2011
Category : Storage Service
Description : Controller event log: Battery relearn pending: Battery is under charge: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 18:11:55 2011
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 23.37%(7303s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 18:11:54 2011
Category : Storage Service
Description : Controller event log: Board Revision A03: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 18:11:54 2011
Category : Storage Service
Description : Controller event log: Firmware initialization started (PCI ID 0079/1000/1f17/1028): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 18:11:54 2011
Category : Storage Service
Description : Controller event log: Battery Present: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 18:11:54 2011
Category : Storage Service
Description : Controller event log: Package version 12.3.0-0032: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 18:11:54 2011
Category : Storage Service
Description : Controller event log: Board Revision A03: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 18:11:54 2011
Category : Storage Service
Description : Controller event log: Enclosure PD 20(c None/p0) communication restored: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 18:11:54 2011
Category : Storage Service
Description : Controller event log: Inserted: Encl PD 20: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 18:11:54 2011
Category : Storage Service
Description : Controller event log: Inserted: PD 00(e0x20/s0): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 18:11:54 2011
Category : Storage Service
Description : Controller event log: Inserted: PD 01(e0x20/s1): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 18:11:54 2011
Category : Storage Service
Description : Controller event log: Background Initialization started on VD 00/0: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 18:11:54 2011
Category : Storage Service
Description : Controller event log: Background Initialization started on VD 01/1: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 18:11:54 2011
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 23.24%(7185s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 18:11:54 2011
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 01/1 is 1.40%(7185s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 18:11:54 2011
Category : Storage Service
Description : Controller event log: Time established as 03/08/11 18:08:44; (37 seconds since power on): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 18:11:54 2011
Category : Storage Service
Description : Controller event log: Battery temperature is normal: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 18:11:53 2011
Category : Storage Service
Description : Controller event log: Shutdown command received from host: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 18:11:53 2011
Category : Storage Service
Description : Controller event log: Firmware initialization started (PCI ID 0079/1000/1f17/1028): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 18:11:53 2011
Category : Storage Service
Description : Controller event log: Battery Present: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 18:11:53 2011
Category : Storage Service
Description : Controller event log: Package version 12.3.0-0032: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 1000
Date and Time : Tue Mar 08 18:11:44 2011
Category : Instrumentation Service
Description : Server Administrator starting

Severity : Critical
ID : 1354
Date and Time : Tue Mar 08 18:11:44 2011
Category : Instrumentation Service
Description : Power supply detected a failure
Sensor location: PS 2 Status
Chassis location: Main System Chassis
Previous state was: Unknown
Power Supply type: AC
Power Supply state: Presence detected, AC lost

Severity : Ok
ID : 1012
Date and Time : Tue Mar 08 18:11:44 2011
Category : Instrumentation Service
Description : IPMI status
Interface: User

Severity : Ok
ID : 1001
Date and Time : Tue Mar 08 18:11:44 2011
Category : Instrumentation Service
Description : Server Administrator startup complete

Severity : Ok
ID : 1008
Date and Time : Tue Mar 08 18:11:44 2011
Category : Instrumentation Service
Description : Systems Management Data Manager Started

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 17:18:46 2011
Category : Storage Service
Description : Controller event log: Battery started charging: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 17:18:46 2011
Category : Storage Service
Description : Controller event log: Current capacity of the battery is above threshold: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 17:18:46 2011
Category : Storage Service
Description : Controller event log: Battery relearn pending: Battery is under charge: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 17:18:46 2011
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 20.14%(4216s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 17:18:43 2011
Category : Storage Service
Description : Controller event log: Shutdown command received from host: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 17:18:43 2011
Category : Storage Service
Description : Controller event log: Firmware initialization started (PCI ID 0079/1000/1f17/1028): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 17:18:43 2011
Category : Storage Service
Description : Controller event log: Battery Present: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 17:18:43 2011
Category : Storage Service
Description : Controller event log: Package version 12.3.0-0032: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 17:18:43 2011
Category : Storage Service
Description : Controller event log: Board Revision A03: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 17:18:43 2011
Category : Storage Service
Description : Controller event log: Firmware initialization started (PCI ID 0079/1000/1f17/1028): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 17:18:43 2011
Category : Storage Service
Description : Controller event log: Battery Present: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 17:18:43 2011
Category : Storage Service
Description : Controller event log: Package version 12.3.0-0032: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 17:18:43 2011
Category : Storage Service
Description : Controller event log: Board Revision A03: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 17:18:43 2011
Category : Storage Service
Description : Controller event log: Enclosure PD 20(c None/p0) communication restored: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 17:18:43 2011
Category : Storage Service
Description : Controller event log: Inserted: Encl PD 20: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 17:18:43 2011
Category : Storage Service
Description : Controller event log: Inserted: PD 00(e0x20/s0): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 17:18:43 2011
Category : Storage Service
Description : Controller event log: Inserted: PD 01(e0x20/s1): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 17:18:43 2011
Category : Storage Service
Description : Controller event log: Background Initialization started on VD 00/0: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 17:18:43 2011
Category : Storage Service
Description : Controller event log: Background Initialization started on VD 01/1: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 17:18:43 2011
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 19.91%(4008s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 17:18:43 2011
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 01/1 is 0.76%(4008s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 17:18:43 2011
Category : Storage Service
Description : Controller event log: Time established as 03/08/11 17:14:49; (38 seconds since power on): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 17:18:43 2011
Category : Storage Service
Description : Controller event log: Battery temperature is normal: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 1000
Date and Time : Tue Mar 08 17:18:33 2011
Category : Instrumentation Service
Description : Server Administrator starting

Severity : Critical
ID : 1354
Date and Time : Tue Mar 08 17:18:33 2011
Category : Instrumentation Service
Description : Power supply detected a failure
Sensor location: PS 2 Status
Chassis location: Main System Chassis
Previous state was: Unknown
Power Supply type: AC
Power Supply state: Presence detected, AC lost

Severity : Ok
ID : 1012
Date and Time : Tue Mar 08 17:18:33 2011
Category : Instrumentation Service
Description : IPMI status
Interface: User

Severity : Ok
ID : 1001
Date and Time : Tue Mar 08 17:18:33 2011
Category : Instrumentation Service
Description : Server Administrator startup complete

Severity : Ok
ID : 1008
Date and Time : Tue Mar 08 17:18:33 2011
Category : Instrumentation Service
Description : Systems Management Data Manager Started

Severity : Ok
ID : 1013
Date and Time : Tue Mar 08 16:51:18 2011
Category : Instrumentation Service
Description : System Peak Power detected new peak value
Peak value (in Watts): 232

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:51:01 2011
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 17.41%(2442s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:51:01 2011
Category : Storage Service
Description : Controller event log: VD 01/1 Properties updated to [ID=01,dcp=0d,ccp=0d,ap=0,dc=0,dbgi=0,S=0|0] (from [ID=01,dcp=0d,ccp=0d,ap=0,dc=0,dbgi=0,S=0|0]): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:51:00 2011
Category : Storage Service
Description : Controller event log: Battery temperature is normal: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:51:00 2011
Category : Storage Service
Description : Controller event log: Battery started charging: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:51:00 2011
Category : Storage Service
Description : Controller event log: Current capacity of the battery is above threshold: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:51:00 2011
Category : Storage Service
Description : Controller event log: Battery relearn pending: Battery is under charge: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:59 2011
Category : Storage Service
Description : Controller event log: Background Initialization started on VD 01/1: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:59 2011
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 17.30%(2358s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:59 2011
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 01/1 is 0.39%(2358s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:59 2011
Category : Storage Service
Description : Controller event log: Time established as 03/08/11 16:46:21; (54 seconds since power on): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:58 2011
Category : Storage Service
Description : Controller event log: Inserted: Encl PD 20: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:58 2011
Category : Storage Service
Description : Controller event log: Inserted: PD 00(e0x20/s0): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:58 2011
Category : Storage Service
Description : Controller event log: Inserted: PD 01(e0x20/s1): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:58 2011
Category : Storage Service
Description : Controller event log: Background Initialization started on VD 00/0: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:57 2011
Category : Storage Service
Description : Controller event log: Battery Present: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:57 2011
Category : Storage Service
Description : Controller event log: Package version 12.3.0-0032: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:57 2011
Category : Storage Service
Description : Controller event log: Board Revision A03: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:57 2011
Category : Storage Service
Description : Controller event log: Enclosure PD 20(c None/p0) communication restored: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:56 2011
Category : Storage Service
Description : Controller event log: Battery Present: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:56 2011
Category : Storage Service
Description : Controller event log: Package version 12.3.0-0032: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:56 2011
Category : Storage Service
Description : Controller event log: Board Revision A03: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:56 2011
Category : Storage Service
Description : Controller event log: Firmware initialization started (PCI ID 0079/1000/1f17/1028): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:55 2011
Category : Storage Service
Description : Controller event log: BBU enabled; changing WT virtual disks to WB: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:55 2011
Category : Storage Service
Description : Controller event log: Policy change on VD 00/0 to [ID=00,dcp=0d,ccp=0d,ap=0,dc=0,dbgi=0,S=0|0] from [ID=00,dcp=0d,ccp=0c,ap=0,dc=0,dbgi=0,S=0|0]: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:55 2011
Category : Storage Service
Description : Controller event log: Policy change on VD 01/1 to [ID=01,dcp=0d,ccp=0d,ap=0,dc=0,dbgi=0,S=0|0] from [ID=01,dcp=0d,ccp=0c,ap=0,dc=0,dbgi=0,S=0|0]: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:55 2011
Category : Storage Service
Description : Controller event log: Firmware initialization started (PCI ID 0079/1000/1f17/1028): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:54 2011
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 16.07%(2197s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:54 2011
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 16.93%(2213s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:54 2011
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 17.16%(2231s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:54 2011
Category : Storage Service
Description : Controller event log: Current capacity of the battery is above threshold: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:53 2011
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 13.92%(2026s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:53 2011
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 14.17%(2119s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:53 2011
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 14.42%(2165s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:53 2011
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 15.21%(2181s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:52 2011
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 12.51%(1885s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:52 2011
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 13.05%(1901s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:52 2011
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 13.53%(1917s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:52 2011
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 13.82%(1933s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:51 2011
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 9.56%(1821s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:51 2011
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 10.44%(1837s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:51 2011
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 11.30%(1853s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:51 2011
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 11.97%(1869s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:50 2011
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 6.87%(1757s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:50 2011
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 7.55%(1773s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:50 2011
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 8.05%(1789s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:50 2011
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 8.68%(1805s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:49 2011
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 3.48%(1693s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:49 2011
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 4.30%(1709s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:49 2011
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 5.16%(1725s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:49 2011
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 6.03%(1741s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:48 2011
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 2.73%(1443s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:48 2011
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 01/1 is 0.24%(1515s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:48 2011
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 2.98%(1635s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:48 2011
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 3.31%(1651s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:47 2011
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 1.74%(866s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:47 2011
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 2.22%(882s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:47 2011
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 2.24%(898s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:47 2011
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 2.48%(1205s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:46 2011
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 0.74%(581s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:46 2011
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 0.99%(680s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:46 2011
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 1.24%(783s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:46 2011
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 1.49%(848s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:45 2011
Category : Storage Service
Description : Controller event log: Background Initialization started on VD 00/0: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:45 2011
Category : Storage Service
Description : Controller event log: Background Initialization started on VD 01/1: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:45 2011
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 0.24%(198s): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:45 2011
Category : Storage Service
Description : Controller event log: Background Initialization progress on VD 00/0 is 0.49%(477s): Controller 0 (PERC H700 Integrated)

Severity : Non-Critical
ID : 2335
Date and Time : Tue Mar 08 16:50:44 2011
Category : Storage Service
Description : Controller event log: BBU disabled; changing WB virtual disks to WT: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:44 2011
Category : Storage Service
Description : Controller event log: Policy change on VD 00/0 to [ID=00,dcp=0d,ccp=0c,ap=0,dc=0,dbgi=0,S=0|0] from [ID=00,dcp=0d,ccp=0d,ap=0,dc=0,dbgi=0,S=0|0]: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:44 2011
Category : Storage Service
Description : Controller event log: Policy change on VD 01/1 to [ID=01,dcp=0d,ccp=0c,ap=0,dc=0,dbgi=0,S=0|0] from [ID=01,dcp=0d,ccp=0d,ap=0,dc=0,dbgi=0,S=0|0]: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:44 2011
Category : Storage Service
Description : Controller event log: Battery relearn pending: Battery is under charge: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:43 2011
Category : Storage Service
Description : Controller event log: Time established as 03/08/11 16:01:21; (34 seconds since power on): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:43 2011
Category : Storage Service
Description : Controller event log: Battery temperature is normal: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:43 2011
Category : Storage Service
Description : Controller event log: Battery started charging: Controller 0 (PERC H700 Integrated)

Severity : Non-Critical
ID : 2335
Date and Time : Tue Mar 08 16:50:43 2011
Category : Storage Service
Description : Controller event log: Current capacity of the battery is below threshold: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:42 2011
Category : Storage Service
Description : Controller event log: Enclosure PD 20(c None/p0) communication restored: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:42 2011
Category : Storage Service
Description : Controller event log: Inserted: Encl PD 20: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:42 2011
Category : Storage Service
Description : Controller event log: Inserted: PD 00(e0x20/s0): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:42 2011
Category : Storage Service
Description : Controller event log: Inserted: PD 01(e0x20/s1): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:41 2011
Category : Storage Service
Description : Controller event log: Firmware initialization started (PCI ID 0079/1000/1f17/1028): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:41 2011
Category : Storage Service
Description : Controller event log: Battery Present: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:41 2011
Category : Storage Service
Description : Controller event log: Package version 12.3.0-0032: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:41 2011
Category : Storage Service
Description : Controller event log: Board Revision A03: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:40 2011
Category : Storage Service
Description : Controller event log: Firmware initialization started (PCI ID 0079/1000/1f17/1028): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:40 2011
Category : Storage Service
Description : Controller event log: Battery Present: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:40 2011
Category : Storage Service
Description : Controller event log: Package version 12.3.0-0032: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:40 2011
Category : Storage Service
Description : Controller event log: Board Revision A03: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:39 2011
Category : Storage Service
Description : Controller event log: VD bad block table on VD 01/1 is cleared: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:39 2011
Category : Storage Service
Description : Controller event log: Fast initialization started on VD 01/1: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:39 2011
Category : Storage Service
Description : Controller event log: Initialization complete on VD 01/1: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:39 2011
Category : Storage Service
Description : Controller event log: VD bad block table on VD 01/1 is cleared: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:38 2011
Category : Storage Service
Description : Controller event log: Initialization complete on VD 00/0: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:38 2011
Category : Storage Service
Description : Controller event log: VD bad block table on VD 00/0 is cleared: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:38 2011
Category : Storage Service
Description : Controller event log: Fast initialization started on VD 01/1: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:38 2011
Category : Storage Service
Description : Controller event log: Initialization complete on VD 01/1: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:37 2011
Category : Storage Service
Description : Controller event log: Created VD 00/0: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:37 2011
Category : Storage Service
Description : Controller event log: VD 00/0 is available: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:37 2011
Category : Storage Service
Description : Controller event log: Policy change on VD 00/0 to [ID=00,dcp=0d,ccp=0c,ap=0,dc=0,dbgi=0,S=0|1] from [ID=00,dcp=0d,ccp=0d,ap=0,dc=0,dbgi=0,S=0|1]: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:37 2011
Category : Storage Service
Description : Controller event log: VD 00/0 Properties updated to [ID=00,dcp=0d,ccp=0c,ap=0,dc=0,dbgi=0,S=0|1] (from [ID=00,dcp=0d,ccp=0c,ap=0,dc=0,dbgi=0,S=0|1]): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:37 2011
Category : Storage Service
Description : Controller event log: VD 01/1 is now OPTIMAL: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:37 2011
Category : Storage Service
Description : Controller event log: Created VD 01/1: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:37 2011
Category : Storage Service
Description : Controller event log: VD 01/1 is available: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:37 2011
Category : Storage Service
Description : Controller event log: Policy change on VD 00/0 to [ID=00,dcp=0d,ccp=0d,ap=0,dc=0,dbgi=0,S=0|1] from [ID=00,dcp=0d,ccp=0c,ap=0,dc=0,dbgi=0,S=0|1]: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:37 2011
Category : Storage Service
Description : Controller event log: Policy change on VD 00/0 to [ID=00,dcp=0d,ccp=0c,ap=0,dc=0,dbgi=0,S=0|1] from [ID=00,dcp=0d,ccp=0d,ap=0,dc=0,dbgi=0,S=0|1]: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:37 2011
Category : Storage Service
Description : Controller event log: Policy change on VD 01/1 to [ID=01,dcp=0d,ccp=0c,ap=0,dc=0,dbgi=0,S=0|1] from [ID=01,dcp=0d,ccp=0d,ap=0,dc=0,dbgi=0,S=0|1]: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:37 2011
Category : Storage Service
Description : Controller event log: Fast initialization started on VD 00/0: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:35 2011
Category : Storage Service
Description : Controller event log: VD 00/0 is now OPTIMAL: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:34 2011
Category : Storage Service
Description : Controller event log: Foreign Configuration Cleared: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:34 2011
Category : Storage Service
Description : Controller event log: Battery relearn pending: Battery is under charge: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:34 2011
Category : Storage Service
Description : Controller event log: State change on PD 00(e0x20/s0) from UNCONFIGURED_GOOD(0) to ONLINE(18): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:34 2011
Category : Storage Service
Description : Controller event log: State change on PD 01(e0x20/s1) from UNCONFIGURED_GOOD(0) to ONLINE(18): Controller 0 (PERC H700 Integrated)

Severity : Non-Critical
ID : 2335
Date and Time : Tue Mar 08 16:50:33 2011
Category : Storage Service
Description : Controller event log: BBU disabled; changing WB virtual disks to WT: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:33 2011
Category : Storage Service
Description : Controller event log: Configuration cleared: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:33 2011
Category : Storage Service
Description : Controller event log: Foreign Configuration Detected: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:33 2011
Category : Storage Service
Description : Controller event log: Foreign Configuration Detected: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:32 2011
Category : Storage Service
Description : Controller event log: Foreign Configuration Detected: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:32 2011
Category : Storage Service
Description : Controller event log: Battery temperature is normal: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:32 2011
Category : Storage Service
Description : Controller event log: Battery started charging: Controller 0 (PERC H700 Integrated)

Severity : Non-Critical
ID : 2335
Date and Time : Tue Mar 08 16:50:32 2011
Category : Storage Service
Description : Controller event log: Current capacity of the battery is below threshold: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:31 2011
Category : Storage Service
Description : Controller event log: Inserted: PD 01(e0x20/s1): Controller 0 (PERC H700 Integrated)

Severity : Non-Critical
ID : 2335
Date and Time : Tue Mar 08 16:50:31 2011
Category : Storage Service
Description : Controller event log: Previous configuration completely missing at boot: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:31 2011
Category : Storage Service
Description : Controller event log: Time established as 03/08/11 15:57:14; (56 seconds since power on): Controller 0 (PERC H700 Integrated)

Severity : Non-Critical
ID : 2335
Date and Time : Tue Mar 08 16:50:31 2011
Category : Storage Service
Description : Controller event log: Patrol Read can't be started, as PDs are either not ONLINE, or are in a VD with an active process, or are in an excluded VD: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:30 2011
Category : Storage Service
Description : Controller event log: Unexpected sense: Encl PD 20 Path 5942b0b05992e500, CDB: 1c 01 00 00 20 00, Sense: 6/29/00: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:30 2011
Category : Storage Service
Description : Controller event log: Enclosure PD 20(c None/p0) communication restored: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:30 2011
Category : Storage Service
Description : Controller event log: Inserted: Encl PD 20: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:30 2011
Category : Storage Service
Description : Controller event log: Inserted: PD 00(e0x20/s0): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:29 2011
Category : Storage Service
Description : Controller event log: Battery Present: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:29 2011
Category : Storage Service
Description : Controller event log: Package version 12.3.0-0032: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:29 2011
Category : Storage Service
Description : Controller event log: Board Revision A03: Controller 0 (PERC H700 Integrated)

Severity : Critical
ID : 2336
Date and Time : Tue Mar 08 16:50:29 2011
Category : Storage Service
Description : Controller event log: Controller cache discarded due to memory/battery problems: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:28 2011
Category : Storage Service
Description : Controller event log: Package version 12.3.0-0032: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:28 2011
Category : Storage Service
Description : Controller event log: Board Revision A03: Controller 0 (PERC H700 Integrated)

Severity : Critical
ID : 2336
Date and Time : Tue Mar 08 16:50:28 2011
Category : Storage Service
Description : Controller event log: Controller cache discarded due to memory/battery problems: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:28 2011
Category : Storage Service
Description : Controller event log: Firmware initialization started (PCI ID 0079/1000/1f17/1028): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:27 2011
Category : Storage Service
Description : Controller event log: Battery charge complete: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:27 2011
Category : Storage Service
Description : Controller event log: Firmware initialization started (PCI ID 0079/1000/1f17/1028): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:27 2011
Category : Storage Service
Description : Controller event log: Battery Present: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:27 2011
Category : Storage Service
Description : Controller event log: Package version 12.3.0-0032: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:27 2011
Category : Storage Service
Description : Controller event log: Board Revision A03: Controller 0 (PERC H700 Integrated)

Severity : Critical
ID : 2336
Date and Time : Tue Mar 08 16:50:27 2011
Category : Storage Service
Description : Controller event log: Controller cache discarded due to memory/battery problems: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:27 2011
Category : Storage Service
Description : Controller event log: Firmware initialization started (PCI ID 0079/1000/1f17/1028): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:27 2011
Category : Storage Service
Description : Controller event log: Battery Present: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:27 2011
Category : Storage Service
Description : Controller event log: Package version 12.3.0-0032: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:27 2011
Category : Storage Service
Description : Controller event log: Board Revision A03: Controller 0 (PERC H700 Integrated)

Severity : Critical
ID : 2336
Date and Time : Tue Mar 08 16:50:27 2011
Category : Storage Service
Description : Controller event log: Controller cache discarded due to memory/battery problems: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:27 2011
Category : Storage Service
Description : Controller event log: Unexpected sense: Encl PD 20 Path 5942b0b05992e500, CDB: 1c 01 00 00 20 00, Sense: 6/29/00: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:27 2011
Category : Storage Service
Description : Controller event log: Enclosure PD 20(c None/p0) communication restored: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:27 2011
Category : Storage Service
Description : Controller event log: Inserted: Encl PD 20: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:27 2011
Category : Storage Service
Description : Controller event log: Inserted: PD 00(e0x20/s0): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:27 2011
Category : Storage Service
Description : Controller event log: Inserted: PD 01(e0x20/s1): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:27 2011
Category : Storage Service
Description : Controller event log: Inserted: PD 02(e0x20/s2): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:27 2011
Category : Storage Service
Description : Controller event log: Inserted: PD 03(e0x20/s3): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:27 2011
Category : Storage Service
Description : Controller event log: Inserted: PD 04(e0x20/s4): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:27 2011
Category : Storage Service
Description : Controller event log: Inserted: PD 05(e0x20/s5): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:27 2011
Category : Storage Service
Description : Controller event log: Battery temperature is normal: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:27 2011
Category : Storage Service
Description : Controller event log: Battery started charging: Controller 0 (PERC H700 Integrated)

Severity : Non-Critical
ID : 2335
Date and Time : Tue Mar 08 16:50:27 2011
Category : Storage Service
Description : Controller event log: Current capacity of the battery is below threshold: Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:27 2011
Category : Storage Service
Description : Controller event log: Firmware initialization started (PCI ID 0079/1000/1f17/1028): Controller 0 (PERC H700 Integrated)

Severity : Ok
ID : 2334
Date and Time : Tue Mar 08 16:50:27 2011
Category : Storage Service
Description : Controller event log: Battery Present: Controller 0 (PERC H700 Integrated)

Severity : Critical
ID : 1354
Date and Time : Tue Mar 08 16:50:14 2011
Category : Instrumentation Service
Description : Power supply detected a failure
Sensor location: PS 2 Status
Chassis location: Main System Chassis
Previous state was: Unknown
Power Supply type: AC
Power Supply state: Presence detected, AC lost

Severity : Ok
ID : 1012
Date and Time : Tue Mar 08 16:50:14 2011
Category : Instrumentation Service
Description : IPMI status
Interface: User

Severity : Ok
ID : 1001
Date and Time : Tue Mar 08 16:50:14 2011
Category : Instrumentation Service
Description : Server Administrator startup complete

Severity : Ok
ID : 1008
Date and Time : Tue Mar 08 16:50:14 2011
Category : Instrumentation Service
Description : Systems Management Data Manager Started

Severity : Ok
ID : 1000
Date and Time : Tue Mar 08 16:50:12 2011
Category : Instrumentation Service
Description : Server Administrator starting

Severity : Ok
ID : 2266
Date and Time : Wed Nov 10 16:10:08 2010
Category : Storage Service
Description : Controller log file entry: Battery 0 Controller 0

Severity : Ok
ID : 2248
Date and Time : Wed Nov 10 16:10:08 2010
Category : Storage Service
Description : The controller battery is executing a Learn cycle.: Battery 0 Controller 0

Severity : Ok
ID : 2358
Date and Time : Wed Nov 10 16:09:03 2010
Category : Storage Service
Description : The battery charge cycle is complete.: Battery 0 Controller 0

Severity : Ok
ID : 2176
Date and Time : Wed Nov 10 16:09:03 2010
Category : Storage Service
Description : The controller battery Learn cycle has started.: Battery 0 Controller 0

Severity : Ok
ID : 1013
Date and Time : Wed Nov 10 16:08:40 2010
Category : Instrumentation Service
Description : System Peak Power detected new peak value
Peak value (in Watts): 227

Severity : Ok
ID : 1304
Date and Time : Wed Nov 10 16:08:23 2010
Category : Instrumentation Service
Description : Redundancy regained
Redundancy unit: System Board PS Redundancy
Chassis location: Main System Chassis
Previous redundancy state was: Unknown

Severity : Ok
ID : 1352
Date and Time : Wed Nov 10 16:07:58 2010
Category : Instrumentation Service
Description : Power supply returned to normal
Sensor location: PS 1 Status
Chassis location: Main System Chassis
Previous state was: Critical (Failed)
Power Supply type: AC
Power Supply state: Presence detected

Severity : Ok
ID : 1000
Date and Time : Wed Nov 10 16:07:35 2010
Category : Instrumentation Service
Description : Server Administrator starting

Severity : Critical
ID : 1354
Date and Time : Wed Nov 10 16:07:35 2010
Category : Instrumentation Service
Description : Power supply detected a failure
Sensor location: PS 1 Status
Chassis location: Main System Chassis
Previous state was: Unknown
Power Supply type: AC
Power Supply state: Presence detected, AC lost

Severity : Ok
ID : 1012
Date and Time : Wed Nov 10 16:07:35 2010
Category : Instrumentation Service
Description : IPMI status
Interface: User

Severity : Ok
ID : 1001
Date and Time : Wed Nov 10 16:07:35 2010
Category : Instrumentation Service
Description : Server Administrator startup complete

Severity : Ok
ID : 1008
Date and Time : Wed Nov 10 16:07:35 2010
Category : Instrumentation Service
Description : Systems Management Data Manager Started

Thanks

 

SAS/SATA Query

$
0
0

Hi,

We have been considering this server :

http://outlet.euro.dell.com/Online/SecondaryInventorySearch.aspx?c=uk&l=en&s=dfb&cs=ukdfb1&puid=b6dfe233

I have a question regarding hard drives. I have 2x 500gb SATA drives I would like to add as separate logical volumes ("D" and "E") alongside the internal SAS drive provided ("C"). The server OS would reside on the 450gb SAS C drive and ideally the 2 500gb SATA drives would function as 2 data drives. Is this possible using the controller provided with this server?

The other drive controller options for this server include PERC 100/300 raid controllers. Can these controllers be used with Windows Server 2012?

Thanks for any advice you can give.

Windows 2003 won't install

$
0
0

I have a poweredge 2900 with 4 sata drives setup as raid 5. When I try to install windows server 2003 it tells me that there are no hard disks installed. I have tried to boot from the Dell Systems Management Tools and Documentation DVD. It says it is loading and then nothing happens. I have tried to download the SBUU tool from dell but there is always a download error. How can I get windows to recognize the virtual drive?

Move from 1 disk to 4 disk raid 5 T-300 SBS 2008

$
0
0
Need to modify 1 disk no-raid to 4 disk raid 5 without backup and restore. What process and procedure would you use? Background, I volunteered to help an organization reconfigure their SBS 2008 server. Last year they received (for free) a Dell T-300 running SBS 2008 with 10 licenses. The organization has nine people. Now for the downside. The machine has 1-250GB hard drive and 4 GB of RAM. The hard drive is split into a 75GB c-drive and the rest is a D-drive for data. The c-drive is completely full (only 100 MB of free space) and the d-drive has only 5 GB of space. They are running AD, File, print and SQL. No Exchange or SharePoint. Originally they had backup to the cloud, but because the software was running on the c drive they removed it. They are now using Windows Backup to a USB drive. They have a few hundred to spend to upgrade it. I will probably upgrade the RAM from 4 GB to 8GB and purchase 3-250GB hard drives to create a raid 5 machine and expand the space. The Dell T-300 machine comes with a perc raid controller so hardware raid is possible. I have also found the same Seagate disks as what is in the machine now. What I normally would do is to back up the hard drive, format, and create raid 5 scenario from scratch, then reinstall but because of some circumstance beyond my control I have very limited time. My plan b is to create a 3 disk software raid 5 for the d-drive and use a partition manger to resize the c-dive. Is there a sane way to rollout the raid 5 from the single disk?

add additional hdd disk

$
0
0

I have added new hdd on dell power edge t320, it is asking for press f for

foreign import configuration, if I choose f , will the data lose or not, kindly suggest me

thanks

saud alam

Upgrade SAS 6 ir to Perc 6i in r610

$
0
0

Looking for some insight on what I though would be a straight up swap.  I changed out my sas 6i card for a perc 6i card using the same cables from the sas 6ir. Booted up, Perc 6i recognized, it recognized my old array, but when I log into the controller during boot to reconfigure the array it will not allow me to configure the a new array/controller.  It sees the drives and the array but no changes allowed. I updated the firmware with same results.

Attached is the error screen shot.  On another forum I read it could require different cables from the card to backplane. The array, drives and old os boots so  I wouldn't think the cables are the wrong ones.  Any ideas would be appreciated.

Cannot update drive firmware in R510

$
0
0

Running Win2k8R2, I donwloaded the latest SUU, and ran the autoupdate for everything. The disk firmware update failed.

So I downloaded the new firmware directly, and tried to run the updater, but it failed again

Here's the information:

Chassis ModelPowerEdge R510
System Revision

II

NamePERC H700 Integrated
State

Ready

Firmware Version12.10.4-0001
Driver Version4.31.01.64
Physical Disk 0:0:0OnlineSpun UpSASHDDKS65Yes931.00GB931.00GB0.00GBNoSEAGATEST31000424SS9WK0ZMHGTH0U738K2123307D01Y9A006.00 Gbps6.00 Gbps052920105000C500211625D1

The firmware I tried to update to is KS6B,A06

Log:

The version of this Update Package is newer than the currently installed version. 
Software application name: ST31000424SS Firmware
Package version: KS6B
Installed version: KS65



Executing update...

Device: ST31000424SS, Application: ST31000424SS Firmware
The operation was not successful because the device buffer write has failed. Run diagnostics to verify configuration and try again.
Any ideas are welcome

H200 to Perc 6i

$
0
0

Called support asked if I could migrate a raid 1 disks on an h200 to a Perc 6i, they were not sure. Wondering if anyone has tried this? Reference on Google for the h200 to h700 but not my scenario. thanks

 

 

Pweredge 1850 win 2003 change from LSI Logic Ultra 320 SCSI to perc 4i

$
0
0

I have an existing installation of windows 2003 server x86. Currently its on LSI Logic Ultra 320 SCSI non raid riser I would like to change it to perc 4i raid riser. The reason I am even doing this is because the server shows plug and play device errors at post. I tried reaseating the riser and also cleared bios but that didn't help. From what I read its either the riser or the motherboard there are no pci cards installed. So I was thinking of getting another 1850 with raid riser and saving the installation.

How can I add the raid driver to the existing windows installation and get windows to boot up?